Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Documents

53404

SAFC

Atto 465 NHS ester

BioReagent, suitable for fluorescence, ≥90% (HPLC)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro MDL:
Code UNSPSC :
12352108
ID de substance PubChem :
Nomenclature NACRES :
NA.25

Gamme de produits

BioReagent

Pureté

≥90% (HPLC)
≥90% (degree of coupling)

Fabricant/nom de marque

ATTO-TEC GmbH

λ

in acetonitrile (with 0.1% acetic acid)

Absorption UV

λ: 454-460 nm Amax

Adéquation

suitable for fluorescence

Température de stockage

−20°C

Chaîne SMILES 

OCl(=O)(=O)=O.Nc1ccc2C=C3C=CC(=N)C=C3N(CCCC(=O)ON4C(=O)CCC4=O)c2c1

InChI

1S/C21H20N4O4.ClHO4/c22-15-5-3-13-10-14-4-6-16(23)12-18(14)24(17(13)11-15)9-1-2-21(28)29-25-19(26)7-8-20(25)27;2-1(3,4)5/h3-6,10-12,22H,1-2,7-9,23H2;(H,2,3,4,5)

Clé InChI

NROCSLJOXCQUHR-UHFFFAOYSA-N

Application

Atto fluorescent labels are designed for high sensitivity applications, including single molecule detection. Atto labels have rigid structures that do not show any cis-trans-isomerization. Thus these labels display exceptional intensity with minimal spectral shift on conjugation.

Informations légales

This product is for Research use only. In case of intended commercialization, please contact the IP-holder (ATTO-TEC GmbH, Germany) for licensing.

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

Eyeshields, Gloves, type N95 (US)


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Slide 1 of 2

1 of 2

David J Posson et al.
Nature, 436(7052), 848-851 (2005-08-12)
Voltage-gated ion channels open and close in response to voltage changes across electrically excitable cell membranes. Voltage-gated potassium (Kv) channels are homotetramers with each subunit constructed from six transmembrane segments, S1-S6 (ref. 2). The voltage-sensing domain (segments S1-S4) contains charged
Radek Macháň et al.
Analytical and bioanalytical chemistry, 399(10), 3547-3554 (2011-02-05)
Z-scan fluorescence correlation spectroscopy (FCS) is employed to characterize the interaction between arenicin-1 and supported lipid bilayers (SLBs) of different compositions. Lipid analogue C8-BODIPY 500/510C5-HPC and ATTO 465 labelled arenicin-1 are used to detect changes in lipid and peptide diffusion
Andriy Chmyrov et al.
Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology, 7(11), 1378-1385 (2008-10-30)
Photo-induced switching of dyes into dark, long-lived states, such as a triplet state, has recently gained increasing interest, as a means to achieve ultra-high optical resolution. Additionally, these long lived states are often highly environment-sensitive and their photodynamics can thus
Gerald Donnert et al.
Proceedings of the National Academy of Sciences of the United States of America, 103(31), 11440-11445 (2006-07-26)
We demonstrate far-field fluorescence microscopy with a focal-plane resolution of 15-20 nm in biological samples. The 10- to 12-fold multilateral increase in resolution below the diffraction barrier has been enabled by the elimination of molecular triplet state excitation as a
Waldemar Waldeck et al.
International journal of medical sciences, 8(2), 97-105 (2011-02-01)
Fluorescent proteins (FPs) are established tools for new applications, not-restricted to the cell biological research. They could also be ideal in surgery enhancing the precision to differentiate between the target tissue and the surrounding healthy tissue. FPs like the KillerRed

Articles

Fluorescent Labeling of Peptides

Fluorescent Labeling of Peptides

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique