DYNA002
DyNAbind® 10 Million Compound DNA-Encoded Library
Synonyme(s) :
DNA encoded library, DNA library
About This Item
Produits recommandés
Forme
pellets
Température de stockage
−20°C
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
- An off-the-shelf kit containing 2 or 5 vials
- Each vial is for testing a single condition
- A detailed user guide with an easy to follow protocol for using the kit
- Analysis instructions for using the web portal to analyze the nextgen sequencing data
Application
All the compounds fit in a single microcentrifuge tube. The compounds can be incubated with a target of interest that is attached to beads. After washing, the compounds bound to the target can be detected. The DNA barcodes are amplified using PCR and then detected using nextgen sequencing. The sequencing data can be loaded to a secure portal on our website for analysis. This will generate a report of the highest affinity compounds that were bound to the target.
Several methods are used to QC the library. The initial single building blocks with their attached DNA barcodes are tested by LC-MS. PCR is used to monitor library assembly, and at completion the library is tested by nextgen sequencing to ensure reasonable compound distribution. The cost of the library includes generating a list of 50 hits or up to 60 hits if there are ties. All the hit structures will be revealed at no additional charge. There are also no additional licensing fees for using the compounds for research and development or manufacturing. This kit saves time since it can be bought and used without the negotiation required for licensing other DEL technologies.
Analysis Portal
We also provide an extended data package (DELDATA) for researchers involved in Artificial Intelligence and Machine Learning for Drug Discovery.
More information about DyNAbind
Caractéristiques et avantages
- 10 Million compound, off-the-shelf, affordable DEL
- Designed by DyNAbind
- Fits in a single microcentrifuge tube
- No sophisticated robotics required to use the kit
- Rapid assay by binding, washing, PCR, and nextgen sequencing
- Free analysis on our website portal
- Structures are revealed for 50 hits or up to 60 with ties at no additional charge
- The label license allows any use of hits in research and development or manufacturing at no additional charge
Conditionnement
- 2 or 5 tubes
- Each tube contains a single lyophilized pellet with 0.3 nmol of the library. The size of the library may vary by batch but will contain at least 10 million compounds.
- The concentration is optimized so that each tube can be used for a single condition. For example, with two tubes, this could be used to test binding to a target and to test a negative control using the beads without a target.
Informations légales
Label License: For R&D use only. Not for drug, household, or other uses. There are no restrictions, additional agreements, or fees required from Merck KGaA or from DyNAbind for using the identified compounds for any purpose.
Code de la classe de stockage
11 - Combustible Solids
Classe de danger pour l'eau (WGK)
WGK 3
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Vous ne trouvez pas la bonne version ?
Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique