Millipore

Millipore Express® SHC High Area (grande surface), Capsule Opticap® XLT

cartridge nominal length 30 in. (75 cm), Opticap® XLT 30

Synonyme(s) :

Gamma Compatible High Area Opticap® XLT 30 Millipore Express® SHC 0.5  µm/ 0.2  µm 1-1/2 in. TC-1 in. HB

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806

Matériaux

polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal

Niveau de qualité

Conformité réglementaire

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Stérilité

non-sterile

Mode de stérilisation compatible

gamma compatible

Gamme de produits

Opticap® XLT 30

Caractéristiques

hydrophilic

Fabricant/nom de marque

Millipore Express®

Paramètres

≤169.2 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure

Technique(s)

sterile filtration: suitable

Longueur

87.1 cm (34.3 in.)

Largeur

7.8 in.

Longueur nominale des cartouches

30 in. (75 cm)

Diamètre

10.7 in. (4.2 cm)

Surface de filtration

3.0 m2

Largeur, de l'entrée à la sortie

17.5 cm (6.9 in.)

Diam. du raccord de sortie

1 in.

Impuretés

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

Matrice

Millipore Express® SHC High Area

pore size

0.5/0.2 μm pore size

Point de bulle

≥4000 mbar (58 psig), air with water at 23 °C

Raccords

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)

Application(s)

sample preparation

Description générale

T-line/Gauge Port: T-line

Conditionnement

Double Easy-Open bag

Autres remarques

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Notes préparatoires

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Remarque sur l'analyse

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 63 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L

Informations légales

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique