MT51344102
Mettler Toledo InLab® Expert Pro ISM-IP67 pH electrode
cable size 1.8 m
About This Item
Produits recommandés
Matériaux
PEEK shaft
glass, U membrane
Description
BNC/RCA (Cinch), IP67
Designed for use with METTLER TOLEDO portable meters SevenGo Duo™ (SG23) and SevenGo Duo pro™ (SG68, SG78 and SG98) only
Reference electrolyte XEROLYT™ Polymer
Reference electrolyte XEROLYT™ Polymer
Reference system ARGENTHAL™
Reference system ARGENTHAL™
Fabricant/nom de marque
Mettler-Toledo 51344102
Plage de mesure de la température
0-100 °C
0-100 °C
L × diam.
120 mm × 12 mm
Taille du câble
1.8 m
Plage de pH
0-14
Adéquation
suitable for (Designed for use with METTLER TOLEDO portable meters SevenGo Duo™ (SG23) and SevenGo Duo pro™ (SG68, SG78 and SG98) only)
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
Ideal for a wide range of applications including emulsions, suspensions, effluent water and solutions containing proteins and sulphides.
The InLab® Expert Pro-ISM electrode has been designed with long life in mind. The fine-pored ceramic junction used in conventional electrodes can easily become contaminated in critical media such as suspensions and wastewater. In contrast the InLab® Expert Pro-ISM electrode with a solid polymeric electrolyte requires no junction at all. As a result these sensors are particularly insensitive to contamination.
The reference electrode on these sensors is in direct contact with the measured medium by means of two open junctions, hence there is no junction to block. In addition, the high grade plastic (PEEK) shaft offers a high level of chemical resistance and robustness. Service life and measurement accuracy are further improved by the ARGENTHAL™ reference system which reduces loss of silver chloride from the reference wire at differing sample temperatures.
The METTLER TOLEDO dual channel portable meters SevenGo Duo™ SG23 and SevenGo Duo pro™ SG68, SG78 and SG98 have the ability to automatically recognize ISM sensors upon connection, transfer calibration data to and from the sensor etc.
• Intelligent sensor management (ISM®)
• High grade plastic shaft (PEEK)
• Polymer electrolyte XEROLYT™
• Open junction
• ARGENTHAL™ reference
• Integrated temperature sensor
Informations légales
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique