Accéder au contenu
MilliporeSigma
Toutes les photos(2)

Key Documents

233528

Sigma-Aldrich

4-Octylaniline

99%

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
CH3(CH2)7C6H4NH2
Numéro CAS:
Poids moléculaire :
205.34
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352100
ID de substance PubChem :
Nomenclature NACRES :
NA.22

Pureté

99%

Indice de réfraction

n20/D 1.516 (lit.)

Point d'ébullition

175 °C/13 mmHg (lit.)

Densité

0.898 g/mL at 25 °C (lit.)

Chaîne SMILES 

CCCCCCCCc1ccc(N)cc1

InChI

1S/C14H23N/c1-2-3-4-5-6-7-8-13-9-11-14(15)12-10-13/h9-12H,2-8,15H2,1H3

Clé InChI

ORKQJTBYQZITLA-UHFFFAOYSA-N

Catégories apparentées

Description générale

Micrometer-sized oil droplet of 4-octylaniline containing 5 mol% of an amphiphilic catalyst exhibits a self-propelled motion, producing tiny oil droplets. Kinetics of proton transfer facilitated by 4-octylaniline across the water/1,2-dichloroethane interface has been investigated by cyclic voltammetry and ac impedance.

Application

4-Octylaniline has been used as an extractant during the extraction of microgram level concentrations of ruthenium(IV) from halide medium. It has also been used in the synthesis of selective benzimidazole based analogs of sphingosine-1-phosphate.

Pictogrammes

Exclamation markEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Acute 1 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

235.4 °F - closed cup

Point d'éclair (°C)

113 °C - closed cup

Équipement de protection individuelle

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Extraction of ruthenium (IV) from hydrochloric acid medium with N-octylaniline and its determination spectrophotometrically with pyrimidine-2-thiol.
Lokhande TN, et al.
Separation Science and Technology, 35(1), 153-168 (2000)
Xu Jie et al.
ACS sensors, 5(1), 40-49 (2019-12-13)
Fluorescent microscopic imaging with the help of small-molecule probes (chemoprobes) is one of the most feasible approaches for noninvasive sensing of intracellular molecules. However, the "always on" property of current chemoprobes failed to achieve time-resolved monitoring. Here, we report the
Kinetics of facilitated proton transfer by hydrophobic aromatic amines across the water/1, 2-dichloroethane interface.
Velazquez-Manzanares M and Schiffrin DJ.
Electrochimica Acta, 49(26), 4651-4658 (2004)
Taro Toyota et al.
Journal of the American Chemical Society, 131(14), 5012-5013 (2009-04-09)
A micrometer-sized oil droplet of 4-octylaniline containing 5 mol % of an amphiphilic catalyst exhibited a self-propelled motion, producing tiny oil droplets, in an aqueous dispersion of an amphiphilic precursor of 4-octylaniline. The tiny droplets on the surface of the
László Szabó et al.
ChemistryOpen, 7(9), 720-729 (2018-09-28)
Given our possible future dependence on carbon fiber reinforced composites, the introduction of a renewable matrix might be advantageous for the vision of a sustainable world. Cellulose is a superior green candidate and provides exceptional freedom in composite design as

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique