Accéder au contenu
MilliporeSigma
Toutes les photos(4)

Key Documents

181994

Sigma-Aldrich

Poly(ethylene oxide)

average Mv 200,000 (nominal), powder

Synonyme(s) :

Polyethylene oxide, PEO

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
(-CH2CH2O-)n
Numéro CAS:
Numéro MDL:
Code UNSPSC :
12352104
ID de substance PubChem :
Nomenclature NACRES :
NA.23

Forme

powder

Niveau de qualité

Poids mol.

average Mv 200,000 (nominal)

Contient

200-500 ppm BHT as inhibitor

Viscosité

65-115 cP, 5 % in H2O(25 °C, Brookfield)(lit.)

Température de transition

Tm 65 °C

Extrémité Ω

hydroxyl

Extrémité α

hydroxyl

Application(s)

battery manufacturing

Chaîne SMILES 

[H]OCCO

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

Clé InChI

LYCAIKOWRPUZTN-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Catégories apparentées

Description générale

Poly(ethylene oxide) (PEO) is a synthetichydrophilic polymer available in several molecular weights. It can be obtained by the ring-opening polymerization ofethylene oxide. It is a semicrystalline polymer with high ionic conductivitycommonly used as a solid polymer electrolyte.

Application

Poly(ethylene oxide) can be used to prepare polymer electrolyte systems for energy storage and conversion devices such as all-solid-state lithium-ion batteries (ASLBs).

This biocompatible polymer can be widely used in the field of biomedical research and tissue engineering. For example, it can be used in the fabrication of biodegradable polyurethane/graphene oxide scaffolds.

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 1

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in
M Patel Geeta et al.
Current drug delivery, 6(2), 159-165 (2009-05-20)
Carbamazepine indicated for the control of epilepsy, undergoes extensive hepatic first-pass metabolism after oral administration. A vaginal dosage form of carbamazepine is not commercially available. Conventional suppository having poor retention in the vaginal tract, as they are removed in a
P I Polimeni et al.
Journal of cardiovascular pharmacology, 14(3), 374-380 (1989-09-01)
The acute hemodynamic effects of an intravenously (i.v.) injected poly(ethylene oxide), Polyox WSR N-60K (dose 50 mg/kg), were studied in the open-chest rat anesthetized with sodium pentobarbital. The injectate is one of four drag-reducing polymers known to augment in vitro
I L Konorova et al.
Patologicheskaia fiziologiia i eksperimental'naia terapiia, (4)(4), 7-9 (1991-07-01)
The search for antiaggregatory compounds is undertaken, as a rule, under in vitro conditions which do not reflect the dynamics of the real process. The present work deals with study of the peculiarities of the development of the collagen induced

Articles

Progress in biotechnology fields such as tissue engineering and drug delivery is accompanied by an increasing demand for diverse functional biomaterials. One class of biomaterials that has been the subject of intense research interest is hydrogels, because they closely mimic the natural environment of cells, both chemically and physically and therefore can be used as support to grow cells. This article specifically discusses poly(ethylene glycol) (PEG) hydrogels, which are good for biological applications because they do not generally elicit an immune response. PEGs offer a readily available, easy to modify polymer for widespread use in hydrogel fabrication, including 2D and 3D scaffold for tissue culture. The degradable linkages also enable a variety of applications for release of therapeutic agents.

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique