Accéder au contenu
Merck

Simple approach to study biomolecule adsorption in polymeric microfluidic channels.

Analytica chimica acta (2012-12-26)
Vladimir Gubala, Jonathan Siegrist, Ruairi Monaghan, Brian O'Reilly, Ram Prasad Gandhiraman, Stephen Daniels, David E Williams, Jens Ducrée
RÉSUMÉ

Herein a simple analytical method is presented for the characterization of biomolecule adsorption on cyclo olefin polymer (COP, trade name: Zeonor(®)) substrates which are widely used in microfluidic lab-on-a-chip devices. These Zeonor(®) substrates do not possess native functional groups for specific reactions with biomolecules. Therefore, depending on the application, such substrates must be functionalized by surface chemistry methods to either enhance or suppress biomolecular adsorption. This work demonstrates a microfluidic method for evaluating the adsorption of antibodies and oligonucleotides surfaces. The method uses centrifugal microfluidic flow-through chips and can easily be implemented using common equipment such as a spin coater. The working principle is very simple. The user adds 40 L of the solution containing the sample to the starting side of a microfluidic channel, where it is moved through by centrifugal force. Some molecules are adsorbed in the channel. The sample is then collected at the other end in a small reservoir and the biomolecule concentration is measured. As a pilot application, we characterized the adsorption of goat anti-human IgG and a 20-mer DNA on Zeonor(®), and on three types of functionalized Zeonor: 3-aminopropyltriethoxysilane (APTES) modified surface with mainly positive charge, negatively charged surface with immobilized bovine serum albumin (BSA), and neutral, hydrogel-like film with polyethylene glycol (PEG) characteristics. This simple analytical approach adds to the fundamental understanding of the interaction forces in real, microfluidic systems. This method provides a straightforward and rapid way to screen surface compositions and chemistry, and relate these to their effects on the sensitivity and resistance to non-specific binding of bioassays using them. In an additional set of experiments, the surface area of the channels in this universal microfluidic chip was increased by precision milling of microscale trenches. This modified surface was then coated with APTES and tested for its potential to serve as a unique protein dilution feature.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
(3-aminopropyl)triéthoxysilane, 99%
Sigma-Aldrich
(3-aminopropyl)triéthoxysilane, ≥98.0%
Sigma-Aldrich
(3-aminopropyl)triéthoxysilane, ≥98%
Sigma-Aldrich
(3-aminopropyl)triéthoxysilane, packaged for use in deposition systems, ≥98%