Skip to Content
Merck
  • 1,5-anhydroglucitol and postprandial hyperglycemia as measured by continuous glucose monitoring system in moderately controlled patients with diabetes.

1,5-anhydroglucitol and postprandial hyperglycemia as measured by continuous glucose monitoring system in moderately controlled patients with diabetes.

Diabetes care (2006-05-30)
Kathleen M Dungan, John B Buse, Joseph Largay, Mary M Kelly, Eric A Button, Shuhei Kato, Steven Wittlin
ABSTRACT

Postprandial hyperglycemia is often inadequately assessed in diabetes management. Serum 1,5-anhydroglucitol (1,5-AG) drops as serum glucose rises above the renal threshold for glucose and has been proposed as a marker for postprandial hyperglycemia. The objective of this study is to demonstrate the relationship between 1,5-AG and postprandial hyperglycemia, as assessed by the continuous glucose monitoring system (CGMS) in suboptimally controlled patients with diabetes. Patients with type 1 or type 2 diabetes and an HbA(1c) (A1C) between 6.5 and 8% with stable glycemic control were recruited from two sites. A CGMS monitor was worn for two consecutive 72-h periods. Mean glucose, mean postmeal maximum glucose (MPMG), and area under the curve for glucose above 180 mg/dl (AUC-180), were compared with 1,5-AG, fructosamine (FA), and A1C at baseline, day 4, and day 7. 1,5-AG varied considerably between patients (6.5 +/- 3.2 mug/ml [means +/- SD]) despite similar A1C (7.3 +/- 0.5%). Mean 1,5-AG (r = -0.45, P = 0.006) correlated with AUC-180 more robustly than A1C (r = 0.33, P = 0.057) or FA (r = 0.38, P = 0.88). MPMG correlated more strongly with 1,5-AG (r = -0.54, P = 0.004) than with A1C (r = 0.40, P = 0.03) or FA (r = 0.32, P = 0.07). 1,5-AG reflects glycemic excursions, often in the postprandial state, more robustly than A1C or FA. 1,5-AG may be useful as a complementary marker to A1C to assess glycemic control in moderately controlled patients with diabetes.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Estriol, meets USP testing specifications
Sigma-Aldrich
Estriol, ≥97%
Sigma-Aldrich
L-Carnitine inner salt, synthetic, ≥98%
Sigma-Aldrich
3-Methyl-L-histidine
Sigma-Aldrich
Glycerol, for molecular biology, ≥99.0%
Sigma-Aldrich
Methylglyoxal solution, ~40% in H2O
Sigma-Aldrich
Glycerol, tested according to Ph. Eur., anhydrous
Sigma-Aldrich
Glycerol, BioUltra, for molecular biology, anhydrous, ≥99.5% (GC)
Sigma-Aldrich
Dimethylamine solution, 40 wt. % in H2O
Supelco
4-Heptanone, analytical standard
Sigma-Aldrich
4-Heptanone, 98%
Sigma-Aldrich
4-Heptanone, ≥97%, FG
Sigma-Aldrich
Methylglyoxal solution, technical, ~40% in H2O
Sigma-Aldrich
(R)-3-Hydroxybutyric acid, ≥98.0% (T)
Sigma-Aldrich
1-Methyl-L-histidine, ≥98.0% (TLC)
Sigma-Aldrich
Butyl alcohol, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
Glycerol, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)
Sigma-Aldrich
Glycerol, BioXtra, ≥99% (GC)
Sigma-Aldrich
Glycerol, ≥99.5%
Sigma-Aldrich
Glycerin, meets USP testing specifications
Sigma-Aldrich
Dimethylamine solution, 2.0 M in methanol
Sigma-Aldrich
Glycerol, FCC, FG
Sigma-Aldrich
Dimethylamine solution, 2.0 M in THF
Levocarnitine, European Pharmacopoeia (EP) Reference Standard
Supelco
Estriol solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Glycerin, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Glycerol, ACS reagent, ≥99.5%
Sigma-Aldrich
Glycerol, ReagentPlus®, ≥99.0% (GC)
Sigma-Aldrich
1-Butanol, for molecular biology, ≥99%
Sigma-Aldrich
Chromium, powder, ≥99% trace metals basis, <45 μm