Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

44897-U

Supelco

ASTM® D6584 Tricaprin Solution

greener alternative

8000 μg/mL in pyridine, analytical standard

Sinónimos:

Biodiesel impurity

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número de CAS:
EC Number:
UNSPSC Code:
41116107
NACRES:
NA.24

grade

analytical standard

agency

ASTM® D6584

form

liquid

packaging

pkg of 1 × 5 mL

greener alternative product characteristics

Design for Energy Efficiency
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

concentration

8000 μg/mL in pyridine

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

petroleum

format

single component solution

greener alternative category

storage temp.

2-8°C

InChI

1S/C33H62O6/c1-4-7-10-13-16-19-22-25-31(34)37-28-30(39-33(36)27-24-21-18-15-12-9-6-3)29-38-32(35)26-23-20-17-14-11-8-5-2/h30H,4-29H2,1-3H3

InChI key

LADGBHLMCUINGV-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials

pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

68.0 °F - closed cup

flash_point_c

20 °C - closed cup

ppe

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

J F Horowitz et al.
Journal of applied physiology (Bethesda, Md. : 1985), 88(1), 219-225 (2000-01-21)
This investigation determined whether ingestion of a tolerable amount of medium-chain triglycerides (MCT; approximately 25 g) reduces the rate of muscle glycogen use during high-intensity exercise. On two occasions, seven well-trained men cycled for 30 min at 84% maximal O(2)
K Shirai et al.
Metabolism: clinical and experimental, 41(11), 1161-1164 (1992-11-01)
We have previously reported lipoprotein lipase with a defect of lipid-interface recognition in a patient with type I hyperlipoproteinemia. In this patient, lipoprotein lipase from post-heparin plasma (PHP) hydrolyzed monomeric substrate tributyrin, but scarcely hydrolyzed triolein emulsified with Triton X-100
Physical behavior of lipase substrates.
D M Small
Methods in enzymology, 286, 153-167 (1997-01-01)
F Kang et al.
AAPS PharmSciTech, 2(4), 30-30 (2004-01-20)
The purpose of this study was to investigate the effect of 2 additives, poly(ethylene glycol) (PEG) 1000 and 1,2,3-tridecanoyl glycerol (tricaprin), on the physico-chemical characteristics and in vitro release of a model protein, bovine serum albumin (BSA), form poly(D,L-lactic-co-glycolic acid)
Elisabetta Esposito et al.
Pharmaceutical research, 25(7), 1521-1530 (2008-01-04)
The present investigation describes a formulative study for the development of innovative drug delivery systems for bromocriptine. Solid lipid nanoparticles (SLN) based on different lipidic components have been produced and characterized. Morphology and dimensional distribution have been investigated by electron

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.