1.15498
HPTLC plates, Silica gel 60 RP-18 F₂₅₄s with concentrating zone 20 x 2.5 cm
pkg of 25 plates, plate L × W 20 cm × 10 cm, glass support
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Productos recomendados
material
glass support
silica gel 60 matrix
Quality Level
feature
binder Organic Polymer
fluorescent indicator
packaging
pkg of 25 plates
technique(s)
HPTLC: suitable
layer thickness
150-200 μm
plate L × W
20 cm × 10 cm
particle size
5-6 μm
pore size
60 Å medium pore diameter
storage temp.
2-30°C
General description
25 Glass plates 20 x 10 cm
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. Our concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the second is a selective layer for separation. Regardless of the spots’ shape, size, or position, the sample always concentrates as a narrow band where the two adsorbents overlap and where the separation starts. These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples.
Linkage
Replaces: 15498-6; 15498
Analysis Note
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
layer thickness concentrating zone: 70 - 110 µm
Fluctuation in the thickness of the concentration zone: ≤ 35 µm
Chromatographic testings:
A) cholesterin test
hRf-values
- cholesterin, cholesterin test:
11 - 23
B) Steroide test
- methyltestosterone, steroid test: 20 - 40
- Reichstein S, steroid test: 50 - 70
- hydrocortisone, steroid test: 65 - 85
Typical value determined on a activated plate (120°C, 15 min)
Eluent a) acetone/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
layer thickness concentrating zone: 70 - 110 µm
Fluctuation in the thickness of the concentration zone: ≤ 35 µm
Chromatographic testings:
A) cholesterin test
hRf-values
- cholesterin, cholesterin test:
11 - 23
B) Steroide test
- methyltestosterone, steroid test: 20 - 40
- Reichstein S, steroid test: 50 - 70
- hydrocortisone, steroid test: 65 - 85
Typical value determined on a activated plate (120°C, 15 min)
Eluent a) acetone/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico