MilliporeSigma
  • Home
  • Search Results
  • Key changes in wine aroma active compounds during bottle storage of Spanish red wines under different oxygen levels.

Key changes in wine aroma active compounds during bottle storage of Spanish red wines under different oxygen levels.

Journal of agricultural and food chemistry (2014-10-07)
Vicente Ferreira, Mónica Bueno, Ernesto Franco-Luesma, Laura Culleré, Purificación Fernández-Zurbano
ABSTRACT

Samples from 16 Spanish red wines have been stored for 6 months at 25 °C under different levels of oxygen (0-56 mg/L). Amino acids, metals, and phenolic compounds were analyzed and related to the production or depletion of key oxidation- and reduction-related aroma compounds. Oxidation brings about sensory-relevant increases in Strecker aldehydes, 1-octen-3-one, and vanillin. Formation of Strecker aldehydes correlates to the wine content on the corresponding amino acid precursor, Zn, and caffeic acid ethyl ester and negatively to some flavonols and anthocyanin derivatives. Formation of most carbonyls correlates to wine-combined SO2, suggesting that part of the increments are the result of the release of aldehydes forming bisulfite combinations once SO2 is oxidized. Methanethiol (MeSH) and dimethylsulfide (DMS), but not H2S levels, increase during storage. MeSH increments correlate to methionine levels and proanthocyanidins and negatively to resveratrol and aluminum. H2S, MeSH, and DMS levels all decreased with oxidation, and for the latter two, there are important effects of Mn and pH, respectively.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Hexane, Laboratory Reagent, ≥95%
Supelco
Dichloromethane solution, certified reference material, 200 μg/mL in methanol
Supelco
Dichloromethane, analytical standard, stabilized
Supelco
Dichloromethane, analytical standard
Supelco
Hexane, analytical standard
Supelco
Dichloromethane, Selectophore, ≥99.5%
Supelco
Pentane, analytical standard
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 5 mm × 8 in.
Sigma-Aldrich
Dichloromethane, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Dichloromethane, biotech. grade, 99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Pentane, ≥99% (GC)
Supelco
Methylene Chloride, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Hexane, ReagentPlus®, ≥99%
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Supelco
Hexane, suitable for HPLC, ≥95%
Sigma-Aldrich
Hexane, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Hexane, suitable for HPLC, ≥95%
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Pentane, spectrophotometric grade, ≥99%
Sigma-Aldrich
Dichloromethane, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
Pentane, suitable for HPLC, ≥99.0%
Sigma-Aldrich
Hexane, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99% (GC)