MilliporeSigma
  • Home
  • Search Results
  • Synthesis of g-C3N4/Fe3O4 nanocomposites and application as a new sorbent for solid phase extraction of polycyclic aromatic hydrocarbons in water samples.

Synthesis of g-C3N4/Fe3O4 nanocomposites and application as a new sorbent for solid phase extraction of polycyclic aromatic hydrocarbons in water samples.

Talanta (2014-12-06)
Man Wang, Shihai Cui, Xiaodi Yang, Wentao Bi
ABSTRACT

An easy preparation of g-C3N4/Fe3O4 nanocomposites by chemical co-precipitation has been demonstrated. The as-prepared materials were characterized by X-ray diffraction, transmission electron microscopy, Fourier transform infrared spectroscopy and thermogravimetric analysis. The high affinity of g-C3N4 toward polycyclic aromatic hydrocarbons and the magnetic behavior of Fe3O4 were combined to provide an efficient and simple magnetic solid phase extraction (MSPE). The adsorption and desorption of polycyclic aromatic hydrocarbons on g-C3N4/Fe3O4 were examined. Different factors affecting the magnetic solid phase extraction of polycyclic aromatic hydrocarbons were assessed in terms of adsorption, desorption, and recovery. Under the optimized conditions, the proposed method showed good limits of detection (LOD, S/N=3) in the range of 0.05-0.1 ng mL(-1) and precision in the range of 1.8-5.3% (RSDs, n=3). This method was also successfully applied to the analysis of real water samples; good spiked recoveries over the range of 80.0-99.8% were obtained.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Iron(II) chloride tetrahydrate, 99.99% trace metals basis
Sigma-Aldrich
Phenanthrene, 98%
Supelco
Fluoranthene, analytical standard
Fluoranthene, BCR®, certified reference material
Benz[a]anthracene, BCR®, certified reference material
Sigma-Aldrich
Benz[a]anthracene, 99%
Supelco
Fluoranthene, analytical standard
Supelco
Phenanthrene, analytical standard, for environmental analysis
Supelco
Benz[a]anthracene, analytical standard
Supelco
Benz[a]anthracene, certified reference material, TraceCERT®
Sigma-Aldrich
Fluoranthene, 98%
Supelco
Melting point standard 79-81°C, analytical standard
Sigma-Aldrich
Phenanthrene, sublimed grade, ≥99.5%
Supelco
Phenanthrene, certified reference material, TraceCERT®
Supelco
Fluoranthene, certified reference material, TraceCERT®
Sigma-Aldrich
Iron(II) chloride tetrahydrate, ReagentPlus®, 98%
Sigma-Aldrich
Iron(II) chloride tetrahydrate, puriss. p.a., ≥99.0% (RT)
Supelco
Melamine, analytical standard
Supelco
Melamine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Naphthalene, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Melamine, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Iron(III) chloride hexahydrate, puriss. p.a., reag. Ph. Eur., ≥99%
Sigma-Aldrich
Iron(III) chloride hexahydrate, reagent grade, ≥98%, chunks
Sigma-Aldrich
Anthracene, sublimed grade, ≥99%
Supelco
Acenaphthylene, certified reference material, TraceCERT®
Supelco
Anthracene, analytical standard
Supelco
Anthracene solution, certified reference material, 200 μg/mL in methanol
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Supelco
Acenaphthylene, analytical standard
Supelco
Pyrene, analytical standard