跳轉至內容
Merck
  • Coupling passive sampling and time of flight mass spectrometry for a better estimation of polar pesticide freshwater contamination: Simultaneous target quantification and screening analysis.

Coupling passive sampling and time of flight mass spectrometry for a better estimation of polar pesticide freshwater contamination: Simultaneous target quantification and screening analysis.

Journal of chromatography. A (2015-02-24)
Robin Guibal, Sophie Lissalde, Adeline Charriau, Gaëlle Poulier, Nicolas Mazzella, Gilles Guibaud
摘要

The aim of this study was first to develop and validate an analytical method for the quantification of 35 polar pesticides and 9 metabolites by ultra-high-performance-liquid chromatography combined with a high resolution time-of-flight mass spectrometer detector (UHPLC-(Q)-TOF). Various analytical conditions were investigated (eluent composition and mass parameters) to optimize analyte responses. Analytical performance (linearity, limit of quantification, and accuracy) was then evaluated and interference in the extract of a passive sampler exposed in freshwater (POCIS: Polar Organic Chemical Integrative Sampler) was studied. The proposed quantification method was validated for 43 compounds with variation of calibration slopes below 10% in environmental matrix. For the unvalidated compound DIA (atrazine-desisopropyl: an atrazine metabolite), interference increased the error of concentration determination (50%). The limits of quantification obtained by combining POCIS and UHPLC-(Q)-TOF for 43 target compounds were between 0.1 (terbuthylazine) and 10.7 ng/L (acetochlor). Secondly, the method was successfully applied during a 14-day POCIS river exposure, and gave concentration values similar to a more commonly used triple quadrupole detector regarding concentration, but allowed for the detection of more compounds. Additionally with the targeted compound quantification, the (Q)-TOF mass spectrometer was also used for screening non-target compounds (other pesticides and pharmaceuticals) in POCIS extracts. Moreover, the acquisition of full scan MS data allowed the identification of the polyethylene glycol (PEG) compounds which gave unresolvable interference to DIA, and thus questions the ability of DIA to be used as performance reference compound (PRC) to determine sampling rates in situ. This study therefore illustrates the potential, and proposes a pathway, of UHPLC-(Q)-TOF combined with POCIS in situ pre-concentration for both quantitative and screening analyses of organic contaminants in water.

材料
產品編號
品牌
產品描述

Sigma-Aldrich
乙酸乙酯, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.7%
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
乙酸乙酯, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
甲酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Supelco
甲酸铵, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
甲酸铵, reagent grade, 97%
Sigma-Aldrich
甲酸铵, ≥99.995% trace metals basis
Sigma-Aldrich
甲酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
甲酸, ACS reagent, ≥88%
Sigma-Aldrich
乙酸乙酯, suitable for HPLC, ≥99.8%
Sigma-Aldrich
乙酸乙酯, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
甲酸铵 溶液, BioUltra, 10 M in H2O
Sigma-Aldrich
乙酸乙酯, puriss., meets analytical specification of Ph. Eur., BP, NF, ≥99.5% (GC)
Sigma-Aldrich
乙酸乙酯, anhydrous, 99.8%
Sigma-Aldrich
甲酸铵, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙酸乙酯, ≥99%, FCC, FG
Sigma-Aldrich
乙酸乙酯