  • A high-throughput method for determination of metabolites of organophosphate flame retardants in urine by ultra performance liquid chromatography-high resolution mass spectrometry.

A high-throughput method for determination of metabolites of organophosphate flame retardants in urine by ultra performance liquid chromatography-high resolution mass spectrometry.

Analytica chimica acta (2014-09-10)
Enrique Cequier, Rosa Maria Marcé, Georg Becher, Cathrine Thomsen
摘要

Organophosphate triesters are common flame retardants used in a wide variety of consumer products from which they can migrate and pollute the indoor environment. Humans may thus be continuously exposed to several organophosphate triesters which might be a risk for human health. An analytical method based on direct injection of 5 μL urine into an ultra performance liquid chromatography system coupled to a time-of-flight mass spectrometry has been developed and validated to monitor exposure to organophosphate triesters through their respective dialkyl and diaryl phosphate metabolites (DAPs). The targeted analytes were: di-n-butyl phosphate (DNBP), diphenyl phosphate (DPHP), bis(2-butoxyethyl) phosphate (BBOEP), bis(2-chloroethyl) phosphate (BCEP), bis(1-chloro-2-propyl) phosphate (BCPP) and bis(1,3-dichloro-2-propyl) phosphate (BDCIPP). Separation was achieved in less than 3 min on a short column with narrow diameter and small particle size (50 mm × 2.1 mm × 1.7 μm). Different mobile phases were explored to obtain optimal sensitivity. Acetonitrile/water buffered with 5mM of ammonium hydroxide/ammonium formate (pH 9.2) was the preferred mobile phase. Quantification of DAPs was performed using deuterated analogues as internal standards in synthetic urine (averaged DAP accuracy was 101%; RSD 3%). Low method limits of quantification (MLQ) were obtained for DNBP (0.40 ng mL(-1)), DPHP (0.10 ng mL(-1)), BDCIPP (0.40 ng mL(-1)) and BBOEP (0.60 ng mL(-1)), but not for the most polar DAPs, BCEP (∼12 ng mL(-1)) and BCPP (∼25 ng mL(-1)). The feasibility of the method was tested on 84 morning urine samples from 42 mother and child pairs. Only DPHP was found above the MLQ in the urine samples with geometric mean (GM) concentrations of 1.1 ng mL(-1) and 0.57 ng mL(-1) for mothers and children respectively. BDCIPP was however, detected above the method limit of detection (MLD) with GM of 0.13 ng mL(-1) and 0.20 ng mL(-1). While occasionally detected, the GM of DNBP and BBOEP were below MLD in both groups.

材料
產品編號
品牌
產品描述

Sigma-Aldrich
氢氧化铵 溶液, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
甲酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
氢氧化铵 溶液, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
甲酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
氢氧化铵 溶液, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
甲酸, ACS reagent, ≥88%
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
Sigma-Aldrich
氢氧化铵 溶液, puriss., meets analytical specification of Ph. Eur., 25-30% NH3 basis
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
氢氧化铵 溶液, puriss. p.a. plus, ≥25% NH3 in H2O
Sigma-Aldrich
氢氧化铵 溶液, BioUltra, ~1 M NH3 in H2O (T)
Sigma-Aldrich
甲酸 溶液, BioUltra, 1.0 M in H2O