跳轉至內容
Merck

Unusual false-positive case of urinary screening for buprenorphine.

Journal of clinical laboratory analysis (2011-07-26)
Giuseppe Lippi, Araelsis Romero, Gianfranco Cervellin, Mariella Mercadanti
摘要

Buprenorphine is a centrally acting analgesic drug that is administered for the management of opioid dependence and as an analgesic drug for the treatment of chronic pain. The growing use of this substance has determined an increased need for laboratory testing for either detection and confirmation of the illicit use or monitoring compliance as a substitution therapy for opioid dependence. We describe here the case of urinary sample adulteration with exogenous buprenorphine (6,952 ng/ml), which has led to afalse-positive immunoassay test result (14.9 ng/ml) on a subsequent sample due to a phenomenon of instrumental carry-over. This unusual case confirms the importance to take into account adulteration when screening urines for buprenorphine in patients undergoing substitution therapy for opioid dependence, routinely perform a confirmation assay on positive samples, and rule out instrumental carry-over.

材料
產品編號
品牌
產品描述

Supelco
降丙吗啡标准液 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
降丙吗啡标准液 溶液, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®