跳轉至內容
Merck
全部照片(1)

Key Documents

43538

Supelco

三(十二烷基)胺 盐酸盐

Selectophore, ≥98.0% (AT)

同義詞:

三(十二烷基)氯化铵, 三月桂基氯化铵

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C36H75N· HCl
CAS號碼:
分子量::
558.45
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:

產品線

Selectophore

品質等級

化驗

≥98.0% (AT)

形狀

solid

SMILES 字串

Cl.CCCCCCCCCCCCN(CCCCCCCCCCCC)CCCCCCCCCCCC

InChI

1S/C36H75N.ClH/c1-4-7-10-13-16-19-22-25-28-31-34-37(35-32-29-26-23-20-17-14-11-8-5-2)36-33-30-27-24-21-18-15-12-9-6-3;/h4-36H2,1-3H3;1H

InChI 密鑰

GPQCSCQDQNXQSV-UHFFFAOYSA-N

一般說明

Tridodecylamine hydrochloride (TDA-HCl) is a hydrophobic tertiary amine.
Visit our Sensor Applications portal to learn more.

應用

It may be used be as buffer dissolved in toluene and hexane during transesterification of N-Ac-L-TyrOEt with PrOH catalyzing the activity of subtilisin Carlsberg.

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

象形圖

Exclamation mark

訊號詞

Warning

危險聲明

危險分類

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

儲存類別代碼

13 - Non Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

dust mask type N95 (US), Eyeshields, Gloves


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Tridodecylamine and its hydrochloride salt: an organo-soluble buffer for subtilisin Carlsberg in non-polar organic solvents.
Harper, Neil, Barry D. Moore, and Peter J. Halling
Tetrahedron Letters, 41.21, 4223-4227 (2000)
J M Rawlings et al.
Gut, 26(2), 203-207 (1985-02-01)
Plastic electrodes have been developed for measuring pH in the human gastrointestinal tract. The electrodes have a plastic hydrogen ion sensitive membrane sealed to a length of fluid filled PVC tubing. Two recently developed hydrogen ion sensitive ligands have been
M O'Dowd et al.
Journal of biomedical engineering, 10(2), 165-170 (1988-04-01)
Frequent measurement of pH and PCO2 levels of fetal blood during labour provides an insight into the presence and nature of fetal asphyxia, effectiveness of in utero resuscitation and the need for operative delivery. A pH measuring system utilizing a
G T McEwan et al.
Journal of medical engineering & technology, 14(1), 16-20 (1990-01-01)
Incorporation of a ligand into polyvinylchloride allows the production of ion selective electrodes that are soft-bodied and disposable. With features make them especially suitable for clinical, particularly gastroenterological, investigations. We report here on the construction of a combined reference and

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務