03079
Ethylbenzene
analytical standard
Synonym(s):
NSC 406903, Phenylethane
About This Item
Recommended Products
grade
analytical standard
Quality Level
vapor density
3.7 (vs air)
vapor pressure
10 mmHg ( 20 °C)
19 mmHg ( 37.7 °C)
Assay
≥99.5% (GC)
autoignition temp.
810 °F
shelf life
limited shelf life, expiry date on the label
expl. lim.
6.7 %
technique(s)
HPLC: suitable
gas chromatography (GC): suitable
refractive index
n20/D 1.495 (lit.)
n20/D 1.495
bp
136 °C (lit.)
mp
−95 °C (lit.)
density
0.867 g/mL at 25 °C (lit.)
application(s)
cleaning products
cosmetics
environmental
flavors and fragrances
food and beverages
personal care
format
neat
SMILES string
CCc1ccccc1
InChI
1S/C8H10/c1-2-8-6-4-3-5-7-8/h3-7H,2H2,1H3
InChI key
YNQLUTRBYVCPMQ-UHFFFAOYSA-N
Looking for similar products? Visit Product Comparison Guide
General description
Application
- Construction of a multi-bed needle-trap device for sample treatment of volatile organic compounds in indoor air samples collected from an office, corridor, and a laboratory, for their analysis by gas chromatography-flame ionization detector (GC-FID)
- Development of a Carbotrap B sorbent-packed needle-trap device for the sampling of benzene, toluene, ethylbenzene, and xylene isomers from air samples for their analysis by gas chromatography-mass spectrometry (GC-MS)
- Simultaneous detection and quantification of 14 volatile organic compounds (VOCs) from 283 flavored refill liquids, 21 nicotine refill liquids, and 12 cartridges of electronic cigarettes by headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS)
- GC-MS detection of 11 VOCs following their extraction using a dynamic headspace needle-trap device (D-HS-NTD) having ZIF-8-derived nanoporous carbon (ZIF-8-NPC) as an adsorbent, from 20 pen ink samples
- Determination of seven volatile organic compounds in the surgically resected colonic tissue samples of colorectal cancer patients by gas chromatography-mass spectrometry (GC-MS) following their extraction by headspace- and direct injection- based solid phase microextraction (SPME)
Recommended products
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - STOT RE 2
Target Organs
hearing organs
Storage Class Code
3 - Flammable liquids
WGK
WGK 1
Flash Point(F)
71.6 °F - closed cup
Flash Point(C)
22.0 °C - closed cup
Personal Protective Equipment
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Protocols
ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 60 m Column
GC Analysis of Xylene Isomers on SLB®-IL60 - The cresol (methylphenol) isomers are also precursors to many chemicals. This chromatogram of a mix of aromatic and methylphenol compounds was generated using an SLB-IL60 ionic liquid column. Its interaction mechanisms allow the separation of all three xylene isomers, and all three cresol isomers.
Technical article page on -US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on Equity®-1 after Purge & Trap using "M" Trap
This application demonstrates the suitability of the Petrocol column for the efficient analysis of hydrocarbons as listed in ASTM method D5134.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service