Skip to Content
Merck
  • Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-07-27)
Wojciech Ostrowski, Anna Wojakowska, Magdalena Grajzer, Maciej Stobiecki
ABSTRACT

Liquid chromatography coupled to mass spectrometry (MS) with electrospray ionization (ESI) is one of analytical techniques to obtain accurate results of low molecular weight aromatic compounds in biological samples of different origin. The interpretations of mass spectra of these aromatic compounds in the negative spectra registered in the full scan MS mode may be uneasy due to presence of deprotonated molecules [M-H](-) from different co-eluting entities, fragment ions created after the break-up of precursor ions and also ions representing modified molecules clusters. Thus, the first aim of this study was to evaluate general parameters during analysis performed in the full scan MS or MS/MS mode. Secondly, to set general fragmentation rules for aromatic compounds and entities in a complex biological matrix. We established that different groups of low molecular weight phenolic acids form unique adduct ions and additionally registration LC/MS/MS spectra with two different collision energies may allow for differentiating isomeric or isobaric molecules. These findings together with some general fragmentation rules can facilitate identifications of aromatic acids as we outlined in the sample of cold-pressed rose-hip oil and lupine leaves extract.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Homogentisic acid, crystalline
Sigma-Aldrich
Propionic acid, BioReagent, suitable for insect cell culture, ~99%
Supelco
SS Benzoic Acid, 2000 μg/mL in dichloromethane, analytical standard
Supelco
Gallic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
trans-Sinapic acid, analytical standard
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
4-Hydroxybenzoic acid, ≥99%, FG
Supelco
trans-Ferulic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Propionic acid, ACS reagent, ≥99.5%
Sigma-Aldrich
Propionic acid, 99%
Sigma-Aldrich
Isovanillic acid, 97%
Sigma-Aldrich
Benzoic acid, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
trans-Ferulic acid, ≥99%
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Benzoic acid, tested according to Ph. Eur.
Supelco
4-Hydroxybenzoic acid, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Benzoic acid, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
trans-p-Coumaric acid, analytical standard
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Propionic acid, ≥99.5%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99.5% (GC)
Benzoic acid, European Pharmacopoeia (EP) Reference Standard
Ferulic acid, European Pharmacopoeia (EP) Reference Standard
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, ≥99.9% (GC)
Supelco
trans-Ferulic acid, matrix substance for MALDI-MS, ≥99.0% (HPLC)