Skip to Content
Merck
  • In vitro evaluation of effects of sustained anti-TNF release from MPEG-PCL-MPEG and PCL microspheres on human rheumatoid arthritis synoviocytes.

In vitro evaluation of effects of sustained anti-TNF release from MPEG-PCL-MPEG and PCL microspheres on human rheumatoid arthritis synoviocytes.

Journal of biomaterials applications (2014-05-24)
Özge Erdemli, Seza Özen, Dilek Keskin, Ali Usanmaz, Ezgi Deniz Batu, Bülent Atilla, Ayşen Tezcaner
ABSTRACT

Anti-tumor necrosis factor α (TNFα) drugs such as etanercept (ETN) have been mostly used in systemic treatment of rheumatoid arthritis. To eliminate the side effects in long-term treatments and to achieve a local sustained anti-inflammatory effect, a controlled drug delivery system is needed for anti-TNFα drugs. This study aims to develop novel injectable microcarriers of ETN that can provide long-term controlled release of this protein drug upon intra-articular application. In this study, poly(ε-caprolactone) (PCL) and its copolymer with poly(ethylene glycol), methoxypoly(ethylene glycol)-poly(ε-caprolactone)-methoxypoly(ethylene glycol) microspheres (MPEG-PCL-MPEG) were compared for their prospective success in rheumatoid arthritis treatment. Microspheres with smooth surface of a mean particle diameter of approximately 5 μm were prepared with both polymers. MPEG-PCL-MPEG microspheres had higher encapsulation efficiency than PCL microspheres. The activity of encapsulated ETN within MPEG-PCL-MPEG microspheres also retained while 90% of the activity of ETN within PCL microspheres could retain during 90-day release. MPEG-PCL-MPEG microspheres showed faster ETN release compared to PCL microspheres in various release media. Cumulative amounts of ETN released from both types of microspheres were significantly lower in cell culture medium and in synovial fluids than in phosphate buffered saline. This was mainly due to protein adsorption onto microspheres. Hydrophilic MPEG segment enhanced ETN release while preventing protein adsorption on microspheres compared to PCL. Sustained ETN release from microspheres resulted with a significant decrease in pro-inflammatory cytokines (TNFα, IFNγ, IL-6, IL-17) and MMP levels (MMP-3, MMP-13), while conserving viability of fibroblast-like synoviocytes compared to the free drug. Results suggest that MPEG-PCL-MPEG is a potential copolymer of PCL that can be used in development of biomedical materials for effective local treatment purposes in chronic inflammatory arthritis owing to enhanced hydrophilicity. Yet, PCL microspheres are also promising systems having good compatibility to synoviocytes and would be especially the choice for treatment approach requiring longer term and slower release.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Dimethyl sulfoxide, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Dimethyl sulfoxide, for molecular biology
Sigma-Aldrich
Dimethyl sulfoxide, PCR Reagent
Sigma-Aldrich
Dimethyl sulfoxide, meets EP testing specifications, meets USP testing specifications
Sigma-Aldrich
Dimethyl sulfoxide, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Supelco
Dimethyl sulfoxide, analytical standard
Supelco
Dichloromethane, analytical standard
Sigma-Aldrich
Dimethyl sulfoxide, anhydrous, ≥99.9%
Sigma-Aldrich
Dichloromethane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Supelco
Dichloromethane, Selectophore, ≥99.5%
Sigma-Aldrich
Dimethyl sulfoxide, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
Dimethyl sulfoxide, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Dimethyl sulfoxide solution, 50 wt. % in H2O
Supelco
Residual Solvent - Chloroform, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Dimethyl sulfoxide, for inorganic trace analysis, ≥99.99995% (metals basis)
Methylene chloride, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Mouse MMP-3 ELISA Kit, for serum, plasma and cell culture supernatant
Supelco
Methylene Chloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Dichloromethane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Dimethyl sulfoxide, suitable for HPLC, ≥99.7%
Dimethyl sulfoxide, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Dichloromethane, biotech. grade, 99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dimethyl sulfoxide, puriss. p.a., ACS reagent, ≥99.9% (GC)
Sigma-Aldrich
Dichloromethane, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Dimethyl sulfoxide, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Dichloromethane, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dimethyl sulfoxide, puriss. p.a., dried, ≤0.02% water