  • Use of multivariate statistical techniques to optimize the separation of 17 capsinoids by ultra performance liquid chromatography using different columns.

Use of multivariate statistical techniques to optimize the separation of 17 capsinoids by ultra performance liquid chromatography using different columns.

Talanta (2015-01-27)
Janclei P Coutinho, Gerardo F Barbero, Oreto F Avellán, A Garcés-Claver, Helena T Godoy, Miguel Palma, Carmelo G Barroso
ABSTRACT

In this work a multivariate statistical tool (Derringer and Suich optimization) was proposed for the separation of seventeen capsinoids (natural and synthetic) using the UHPLC-DAD chromatography. Capsinoids were analyzed at 280 nm. The variables optimized were the mobile phase (water (0.1% acetic acid as solvent A) and acetonitrile (0.1% as solvent B)), gradient time and flow rate. Two columns with different length (50 and 100 mm) were used for the chromatographic separation. The two columns used properly separated the seventeen capsinoids, however the 100 mm column length showed a better chromatographic separation with a shorter run time and smaller peak widths. These results provided better values of limit of detection and quantification for the 100 mm column length. The better conditions of separation with the 100 mm column length were established with: initial mobile phase with 41.8% of solvent B; 3.96 min of linear gradient time to reach 100% of solvent B; flow rate of 0.679 mL min(-1). A validation of the method has been done with excellent values of repeatability (RSD<1.92) and intermediate precision (RSD<3.92). The developed method has been applied to real samples. Capsiate has been identified and quantified in some varieties of peppers.

MATERIALS
Product Number
Brand
Product Description

Supelco
Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Undecanoic acid, ≥99%, FG
Sigma-Aldrich
tert-Butyldimethylsilyl chloride solution, 1.0 M in methylene chloride
Sigma-Aldrich
Decanoyl chloride, 98%
Sigma-Aldrich
Hexanoyl chloride, ≥99%
Sigma-Aldrich
Lauroyl chloride, 98%
Sigma-Aldrich
Pentadecanoic acid, 99%
Sigma-Aldrich
Ethyl acetate, natural, ≥99%, FCC, FG
Sigma-Aldrich
tert-Butyldimethylsilyl chloride solution, 1.0 M in THF
Sigma-Aldrich
Ethyl acetate, ≥99%, FCC, FG
Sigma-Aldrich
tert-Butyldimethylsilyl chloride, reagent grade, 97%
Sigma-Aldrich
Butyryl chloride, ≥99%
Sigma-Aldrich
Nonanoyl chloride, 96%
Sigma-Aldrich
Hexane, spectrophotometric grade, ≥95%
Sigma-Aldrich
Undecanoic acid, 98%
Supelco
Residual Solvent - Chloroform, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ethanol, purum, secunda spirit, denaturated with 2% 2-butanone, S15, ~96% (based on denaturant-free substance)
Supelco
Nitrite ion standard solution, 0.1 M NO2-, for ion-selective electrodes
Supelco
Hexane, analytical standard
Sigma-Aldrich
Hexanoyl chloride, purum, ≥98.0% (GC)
Sigma-Aldrich
Pentadecanoic acid, ~99% (capillary GC)
Sigma-Aldrich
Tridecanoic acid, ≥98%
Sigma-Aldrich
Hexanoyl chloride, 97%
Supelco
Sodium nitrite, analytical standard
Sigma-Aldrich
Acetonitrile, ≥99.5% (GC)
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Sodium nitrite, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Toluene, ACS reagent, ≥99.5%