跳转至内容
Merck
  • Cyclocoagulation of the ciliary bodies by high-intensity focused ultrasound: a 12-month multicenter study.

Cyclocoagulation of the ciliary bodies by high-intensity focused ultrasound: a 12-month multicenter study.

Investigative ophthalmology & visual science (2015-01-22)
Philippe Denis, Florent Aptel, Jean-François Rouland, Jean-Philippe Nordmann, Yves Lachkar, Jean-Paul Renard, Eric Sellem, Christophe Baudouin, Alain Bron
摘要

To evaluate the safety and efficacy of high-intensity focused ultrasound (HIFU) cyclocoagulation in reducing intraocular pressure (IOP) in patients with refractory glaucoma by using a novel miniaturized delivery device (EyeOP1). We conducted a 12-month open-label multicenter prospective study (EyeMUST1 Study). Patients with primary (primary open-angle glaucoma [POAG]) or secondary refractory glaucoma were treated in two groups depending on the duration of each ultrasound shot (group 1: 4 seconds; group 2: 6 seconds). The primary efficacy outcome was based on IOP reduction at 6 and 12 months. Fifty-two patients were enrolled: 36 (69%) had POAG and 16 (31%) had secondary glaucoma. Group 1 (n = 24) and group 2 (n = 28) had similar demographics and baseline characteristics. In group 1, IOP was reduced from a mean preoperative value of 29.7 ± 7.7 mm Hg (n = 3.5 glaucoma medications) to a mean postoperative value of 21.3 ± 6.7 mm Hg (n = 3.5 glaucoma medications) and 20.1 ± 6.7 mm Hg (n = 3.2 glaucoma medications) at 6 and 12 months, respectively. In group 2, IOP was reduced from a mean preoperative value of 29.0 ± 7.4 mm Hg (n = 3.3 glaucoma medications) to a mean postoperative value of 20.2 ± 7.4 mm Hg (n = 3.4 glaucoma medications) and 18.5 ± 6.6 mm Hg (n = 3.5 glaucoma medications) at 6 and 12 months, respectively. At 12 months, the IOP reduction was sustained in both groups (32% IOP reduction in group 1 and 36% IOP reduction in group 2). The overall tolerance of the technique was good, with no serious adverse events. The new miniaturized HIFU EyeOP1 delivery device seems to be effective in decreasing IOP in patients with refractory glaucoma. The technology offers a good safety profile. (ClinicalTrials.gov number, NCT01338467.).

材料
货号
品牌
产品描述

Sigma-Aldrich
地塞米松, powder, BioReagent, suitable for cell culture, ≥97%
Sigma-Aldrich
地塞米松, ≥98% (HPLC), powder
Sigma-Aldrich
地塞米松, powder, γ-irradiated, BioXtra, suitable for cell culture, ≥80% (HPLC)
Sigma-Aldrich
Tobramycin, Aminoglycoside antibiotic
USP
地塞米松, United States Pharmacopeia (USP) Reference Standard
USP
Tobramycin, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
地塞米松, meets USP testing specifications
Sigma-Aldrich
氟比洛芬, cyclooxygenase inhibitor
Supelco
地塞米松, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Tobramycin, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
氟比洛芬, Pharmaceutical Secondary Standard; Certified Reference Material
Tobramycin, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
地塞米松, tested according to Ph. Eur.
氟比洛芬, European Pharmacopoeia (EP) Reference Standard
Supelco
地塞米松, VETRANAL®, analytical standard
地塞米松, European Pharmacopoeia (EP) Reference Standard
地塞米松, British Pharmacopoeia (BP) Assay Standard
地塞米松, European Pharmacopoeia (EP) Reference Standard
地塞米松, European Pharmacopoeia (EP) Reference Standard