跳转至内容
Merck
  • Detailed compositional characterization of plastic waste pyrolysis oil by comprehensive two-dimensional gas-chromatography coupled to multiple detectors.

Detailed compositional characterization of plastic waste pyrolysis oil by comprehensive two-dimensional gas-chromatography coupled to multiple detectors.

Journal of chromatography. A (2014-07-30)
Hilal E Toraman, Thomas Dijkmans, Marko R Djokic, Kevin M Van Geem, Guy B Marin
摘要

The detailed compositional characterization of plastic waste pyrolysis oil was performed with comprehensive two-dimensional GC (GC×GC) coupled to four different detectors: a flame ionization detector (FID), a sulfur chemiluminescence detector (SCD), a nitrogen chemiluminescence detector (NCD) and a time of flight mass spectrometer (TOF-MS). The performances of different column combinations were assessed in normal i.e. apolar/mid-polar and reversed configurations for the GC×GC-NCD and GC×GC-SCD analyses. The information obtained from the four detectors and the use of internal standards, i.e. 3-chlorothiophene for the FID and the SCD and 2-chloropyridine for the NCD analysis, enabled the identification and quantification of the pyrolysis oil in terms of both group type and carbon number: hydrocarbon groups (n-paraffins, iso-paraffins, olefins and naphthenes, monoaromatics, naphthenoaromatics, diaromatics, naphthenodiaromatics, triaromatics, naphthenotriaromatics and tetra-aromatics), nitrogen (nitriles, pyridines, quinolines, indole, caprolactam, etc.), sulfur (thiols/sulfides, thiophenes/disulfides, benzothiophenes, dibenzothiophenes, etc.) and oxygen containing compounds (ketones, phenols, aldehydes, ethers, etc.). Quantification of trace impurities is illustrated for indole and caprolactam. The analyzed pyrolysis oil included a significant amount of nitrogen containing compounds (6.4wt%) and to a lesser extent sulfur containing compounds (0.6wt%). These nitrogen and sulfur containing compounds described approximately 80% of the total peak volume for respectively the NCD and SCD analysis. TOF-MS indicated the presence of the oxygen containing compounds. However only a part of the oxygen containing compounds (2.5wt%) was identified because of their low concentrations and possible overlap with the complex hydrocarbon matrix as no selective detector or preparative separation for oxygen compounds was used.

材料
货号
品牌
产品描述

Sigma-Aldrich
正己烷, suitable for HPLC, ≥97.0% (GC)
Sigma-Aldrich
正己烷, ReagentPlus®, ≥99%
Sigma-Aldrich
正己烷, suitable for HPLC, ≥95%
Sigma-Aldrich
正己烷, Laboratory Reagent, ≥95%
Sigma-Aldrich
正己烷, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
正己烷, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
L-赖氨酸 单盐酸盐, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
噻吩, ≥99%
Sigma-Aldrich
正己烷, anhydrous, 95%
Sigma-Aldrich
2-氯吡啶, 99%
Sigma-Aldrich
二苯并噻吩, 98%
Sigma-Aldrich
二苯并噻吩, ≥99%
Sigma-Aldrich
硫茚, 98%
Supelco
正己烷, analytical standard
Sigma-Aldrich
L-赖氨酸 单盐酸盐, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
硫茚, 95%
Supelco
L-赖氨酸 单盐酸盐, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
L-赖氨酸 单盐酸盐, BioUltra, ≥99.5% (AT)
赖氨酸 盐酸盐, European Pharmacopoeia (EP) Reference Standard
Supelco
噻吩, analytical standard
Supelco
L-赖氨酸 单盐酸盐, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-赖氨酸盐酸盐 溶液, 100 mM amino acid in 0.1 M HCl, analytical standard
Supelco
二苯并噻吩, analytical standard