Skip to Content
Merck
  • Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry.

Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-03-24)
Yin-Liang Wu, Ruo-Xia Chen, Yong Zhu, Jian Zhao, Ting Yang
ABSTRACT

A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method using multi-walled carbon nanotubes (MWCNTs) as a reversed-dispersive solid phase extraction (r-dSPE) material combined with ultra-high liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed for the simultaneous determination of 16 novel amide fungicides in vegetables and fruits. After extraction with acetonitrile, a dSPE cleanup procedure, which was developed after the optimization of the type and amount of MWCNTs, the pH value of the extract, the extraction time for MWCNTs, and the type of eluent with MWCNTs material, was conducted. The determination of the target compounds was conducted in less than 7.0 min while the specificity is ensured through the MRM acquisition mode. The linearity of the analytical response across the studied range of concentrations (0.25-500 μg/L) was excellent, obtaining correlation coefficients higher than 0.997. The samples were quantified with the matrix matched standard solutions. The average recoveries in cabbage, celery, strawberry, and grape at three spiked levels (0.01, 0.5, and 5.0mg/kg) were ranged from 72.4 to 98.5% with all RSDs lower than 10%. The limits of detection were below 0.003 mg/kg and the limits of quantification did not exceed 0.01 mg/kg in all matrices. The method demonstrated to be suitable for the simultaneous determination of 16 novel amide fungicides in vegetables and fruits.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Sodium hydroxide, anhydrous, free-flowing, Redi-Dri, reagent grade, ≥98%, pellets
Supelco
Fenoxanil, PESTANAL®, analytical standard
Sigma-Aldrich
Methanol, NMR reference standard
Sigma-Aldrich
Sodium hydroxide, ultra dry, powder or crystals, 99.99% trace metals basis
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Cyclohexane, ACS reagent, ≥99%
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Sodium hydroxide, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Sodium hydroxide, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
Sodium hydroxide solution, 5.0 M
Sigma-Aldrich
Sodium hydroxide, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Cyclohexane, ACS reagent, ≥99%
Sigma-Aldrich
Sodium hydroxide, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
Sodium hydroxide solution, 50% in H2O
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Sodium hydroxide, ACS reagent, ≥97.0%, pellets
Supelco
Penthiopyrad, PESTANAL®, analytical standard
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, powder
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, flakes