1.51015
TLC aluminum sheets, silica gel 60 RP-18 F254s MS-grade
pkg of 20 sheets, sheet L × W 5 cm × 7.5 cm, aluminum support
Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych
About This Item
Polecane produkty
Materiały
aluminum support
silica gel 60 matrix
Poziom jakości
Właściwości
binder Organic Polymer
fluorescent indicator
opakowanie
pkg of 20 sheets
metody
TLC-MS: suitable
thin layer chromatography (TLC): suitable
grubość warstwy
100 μm
arkusz dł. × szer.
5 cm × 7.5 cm
wielkość cząstki
10-12 μm
wielkość porów
60 Å medium pore diameter
temp. przechowywania
2-30°C
Opis ogólny
20 Aluminium sheets 5x7.5
Reference:
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Komentarz do analizy
Specific surface area(according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
This page may contain text that has been machine translated.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej