Skip to Content
Merck
  • Optimization of supercritical fluid consecutive extractions of fatty acids and polyphenols from Vitis vinifera grape wastes.

Optimization of supercritical fluid consecutive extractions of fatty acids and polyphenols from Vitis vinifera grape wastes.

Journal of food science (2014-12-05)
Oier Aizpurua-Olaizola, Markel Ormazabal, Asier Vallejo, Maitane Olivares, Patricia Navarro, Nestor Etxebarria, Aresatz Usobiaga
ABSTRACT

In this study, supercritical fluid extraction has been successfully applied to a sequential fractionation of fatty acids and polyphenols from wine wastes (2 different vitis vinifera grapes). To this aim, in a 1st step just fatty acids were extracted and in a 2nd one the polyphenols. The variables that affected to the extraction efficiency were separately optimized in both steps following an experimental design approach. The effect of extraction temperature flow, pressure, and time were thoroughly evaluated for the extraction of fatty acids, whereas the addition of methanol was also considered in the case of the polyphenols extraction. A quantitative extraction with high efficiency was achieved at a very short time and low temperatures. Concerning quantification, fatty acids were determined by means of gas chromatography coupled to mass spectrometry after a derivatization step, whereas the polyphenols were analyzed by means of high performance liquid chromatography coupled to tandem mass spectrometry and the Folin-Ciocalteu method.

MATERIALS
Product Number
Brand
Product Description

Supelco
trans-9-Octadecenoic acid methyl ester, certified reference material, 10 mg/mL in heptane, ampule of 1 mL
Sigma-Aldrich
2,2,4-Trimethylpentane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.5%
Sigma-Aldrich
2,2,4-Trimethylpentane, suitable for HPLC, ≥99%
Sigma-Aldrich
Methyl behenate, ≥98.5% (capillary GC)
Sigma-Aldrich
Methyl cis-11-eicosenoate, ≥98%
Supelco
Methyl behenate, analytical standard
Supelco
Methyl octanoate, analytical standard
Sigma-Aldrich
Methyl linolenate, ≥99% (GC)
Sigma-Aldrich
Gallic acid, 97.5-102.5% (titration)
Sigma-Aldrich
2,2,4-Trimethylpentane, ACS reagent, ≥99.0%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Methyl oleate, technical grade, 70%
Sigma-Aldrich
Sodium carbonate-12C, 99.9 atom % 12C
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Methyl laurate, ≥98%, FG
Sigma-Aldrich
Methyl octanoate, 99%, FG
Sigma-Aldrich
Methyl oleate, 99%
Supelco
Methyl oleate, analytical standard
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Methyl laurate, 99.5%
Supelco
Methyl heptadecanoate, analytical standard
Supelco
Methyl pentadecanoate, analytical standard
Supelco
Sulfuric acid concentrate, 0.1 M H2SO4 in water (0.2N), eluent concentrate for IC
Supelco
Sodium carbonate concentrate, 0.1 M Na2CO3 in water, eluent concentrate for IC
Supelco
Gallic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Methyl laurate, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Methyl linoleate, ≥98% (GC)
Sigma-Aldrich
Methyl elaidate, ≥99% (capillary GC)
Sigma-Aldrich
Methyl arachidate, ≥99% (capillary GC)
Sigma-Aldrich
Methyl tridecanoate, ≥97% (GC)