Skip to Content
Merck
  • Fast determination of 22 sulfonamides from chicken breast muscle using core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer followed by liquid chromatography-tandem mass spectrometry.

Fast determination of 22 sulfonamides from chicken breast muscle using core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer followed by liquid chromatography-tandem mass spectrometry.

Journal of chromatography. A (2014-05-02)
Yong-Gang Zhao, Li-Xin Zhou, Sheng-Dong Pan, Ping-Ping Zhan, Xiao-Hong Chen, Mi-Cong Jin
ABSTRACT

A novel, simple and sensitive method was developed for the simultaneous determination of 22 sulfonamides (SAs) in chicken breast muscle by using the dispersive micro-solid-phase extraction (d-μ-SPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS). The excellent core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer (CS-NR-Mag-MIP) was used as sorbent, and the main factors affecting the extraction efficiency were investigated in detail. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.9980. The mean recoveries were in the range of 85.0-112.2% at low, medium and high concentration levels (0.1, 1.0 and 5.0 ng/g). The intra-day and inter-day relative standard deviations (RSDs) were lower than 6.0% and 8.9%, respectively. The limits of quantification for the 22 SAs were between 0.013 and 0.099 ng/g. The developed d-μ-SPE-UFLC-MS/MS method had been successfully applied to the chicken breast muscle samples for food-safety risk monitoring in Zhejiang Province, China. The results showed sulfamethazine, sulfamethoxazole and sulfaquinoxaline in five out of three hundred collected samples were detected with concentrations of 0.418-2.28, 16.4 and 2.93 ng/g, respectively. It was confirmed that the CS-NR-Mag-MIP was a kind of highly effective d-μ-SPE materials used for the SAs analyses.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Supelco
Sulfaquinoxaline, PESTANAL®, analytical standard
Sigma-Aldrich
Glycidyl methacrylate, 97%, contains 100 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Methyl methacrylate, contains ≤30 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
Luperox® A75, Benzoyl peroxide, 75%, remainder water
Sigma-Aldrich
Methyl methacrylate, 99%, stabilized
Sigma-Aldrich
Glycidyl methacrylate, ≥97.0% (GC)
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Ammonium acetate, ≥99.99% trace metals basis
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Oleic acid, natural, FCC
Sigma-Aldrich
Oleic acid, technical grade, 90%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Supelco
Sulfamethoxazole, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Sulfamerazine, VETRANAL®, analytical standard
Supelco
Sulfamethoxazole, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Oleic acid, ≥99% (GC)
Sigma-Aldrich
Sulfadiazine, 99.0-101.0%
Supelco
Sulfamethoxazole
Supelco
Oleic acid, analytical standard
USP
Sulfadiazine, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, AR, ≥99.5%
Sigma-Aldrich
Acetonitrile, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%