Skip to Content
Merck
  • Wide injection zone compression in gradient reversed-phase liquid chromatography.

Wide injection zone compression in gradient reversed-phase liquid chromatography.

Journal of chromatography. A (2015-03-10)
Martin Gilar, Thomas S McDonald, Jay S Johnson, James P Murphy, James W Jorgenson
ABSTRACT

Chromatographic zone broadening is a common issue in microfluidic chromatography, where the sample volume introduced on column often exceeds the column void volume. To better understand the propagation of wide chromatographic zones on a separation device, a series of MS Excel spreadsheets were developed to simulate the process. To computationally simplify these simulations, we investigated the effects of injection related zone broadening and its gradient related zone compression by tracking only the movements of zone boundaries on column. The effects of sample volume, sample solvent, gradient slope, and column length on zone broadening were evaluated and compared to experiments performed on 0.32mm I.D. microfluidic columns. The repetitive injection method (RIM) was implemented to generate experimental chromatograms where large sample volume scenarios can be emulated by injecting two discrete small injection plugs spaced in time. A good match between predicted and experimental RIM chromatograms was observed. We discuss the performance of selected retention models on the accuracy of predictions and use the developed spreadsheets for illustration of gradient zone focusing for both small molecules and peptides.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Indole, ≥99%, FG
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Supelco
Acetophenone, analytical standard
Sigma-Aldrich
Butyrophenone, ≥99%
Sigma-Aldrich
Acetophenone, ≥98%, FG
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Butyrophenone, ≥99%
Sigma-Aldrich
Valerophenone, 99%
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Uracil, ≥99.0%
Supelco
Uracil, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, AR, ≥99.5%
Sigma-Aldrich
Acetonitrile, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%