Skip to Content
Merck
  • Can serum beta-hydroxybutyrate be used to diagnose diabetic ketoacidosis?

Can serum beta-hydroxybutyrate be used to diagnose diabetic ketoacidosis?

Diabetes care (2008-01-11)
Mae Sheikh-Ali, Brad S Karon, Ananda Basu, Yogish C Kudva, Lisa A Muller, Jia Xu, W Frederick Schwenk, John M Miles
ABSTRACT

Current criteria for the diagnosis of diabetic ketoacidosis (DKA) are limited by their nonspecificity (serum bicarbonate [HCO(3)] and pH) and qualitative nature (the presence of ketonemia/ketonuria). The present study was undertaken to determine whether quantitative measurement of a ketone body anion could be used to diagnose DKA. A retrospective review of records from hospitalized diabetic patients was undertaken to determine the concentration of serum beta-hydroxybutyrate (betaOHB) that corresponds to a HCO(3) level of 18 mEq/l, the threshold value for diagnosis in recently published consensus criteria. Simultaneous admission betaOHB and HCO(3) values were recorded from 466 encounters, 129 in children and 337 in adults. A HCO(3) level of 18 mEq/l corresponded with betaOHB levels of 3.0 and 3.8 mmol/l in children and adults, respectively. With the use of these threshold betaOHB values to define DKA, there was substantial discordance (approximately > or = 20%) between betaOHB and conventional diagnostic criteria using HCO(3), pH, and glucose. In patients with DKA, there was no correlation between HCO(3) and glucose levels on admission and a significant but weak correlation between betaOHB and glucose levels (P < 0.001). Where available, serum betaOHB levels > or = 3.0 and > or = 3.8 mmol/l in children and adults, respectively, in the presence of uncontrolled diabetes can be used to diagnose DKA and may be superior to the serum HCO(3) level for that purpose. The marked variability in the relationship between betaOHB and HCO(3) is probably due to the presence of other acid-base disturbances, especially hyperchloremic, nonanion gap acidosis.

MATERIALS
Product Number
Brand
Product Description

Supelco
4-Heptanone, analytical standard
Sigma-Aldrich
1-Methyl-L-histidine, ≥98.0% (TLC)
Sigma-Aldrich
Dimethylamine solution, 40 wt. % in H2O
Sigma-Aldrich
Glycerol, tested according to Ph. Eur., anhydrous
Sigma-Aldrich
Glycerol, BioUltra, for molecular biology, anhydrous, ≥99.5% (GC)
Sigma-Aldrich
Methylglyoxal solution, technical, ~40% in H2O
Sigma-Aldrich
4-Heptanone, 98%
Sigma-Aldrich
Butyl alcohol, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
4-Heptanone, ≥97%, FG
Sigma-Aldrich
Dimethylamine solution, 2.0 M in THF
Sigma-Aldrich
Glycerol, FCC, FG
Sigma-Aldrich
Dimethylamine solution, 2.0 M in methanol
Sigma-Aldrich
(R)-3-Hydroxybutyric acid, ≥98.0% (T)
Sigma-Aldrich
Glycerol, BioXtra, ≥99% (GC)
Sigma-Aldrich
Glycerol, ≥99.5%
Sigma-Aldrich
Estriol, ≥97%
Sigma-Aldrich
Estriol, meets USP testing specifications
Sigma-Aldrich
Methylglyoxal solution, ~40% in H2O
Sigma-Aldrich
3-Methyl-L-histidine
Sigma-Aldrich
Glycerol, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)
Sigma-Aldrich
Glycerin, meets USP testing specifications
Sigma-Aldrich
Glycerol, for molecular biology, ≥99.0%
Sigma-Aldrich
L-Carnitine inner salt, synthetic, ≥98%
Sigma-Aldrich
Dimethylamine solution, purum, 33% in absolute ethanol (~5.6 M)
Sigma-Aldrich
Glycerol, ACS reagent, ≥99.5%
Sigma-Aldrich
Glycerol, ReagentPlus®, ≥99.0% (GC)
Supelco
Glycerin, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Estriol solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Levocarnitine, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
1-Butanol, for molecular biology, ≥99%