Skip to Content
Merck
  • Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS.

Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS.

Journal of analytical toxicology (2014-08-12)
David W Andersen, Kristian Linnet
ABSTRACT

A screening method for 18 frequently measured exogenous anabolic steroids and the testosterone/epitestosterone (T/E) ratio in forensic cases has been developed and validated. The method involves a fully automated sample preparation including enzyme treatment, addition of internal standards and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids. Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic steroids. Only seven different steroids including testosterone were found in the material, suggesting that only a small number of common steroids are likely to occur in a forensic context. The steroids were often in high concentrations (>100 ng/mL), and a combination of steroids and/or other drugs of abuse were seen in the majority of cases. The method presented serves as a fast and automated screening procedure, proving the suitability of LC-MS-MS for analyzing anabolic steroids.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Supelco
Testosterone, VETRANAL®, analytical standard
Sigma-Aldrich
17α-Methyltestosterone, solid (photosensitive)
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Supelco
Methanol, analytical standard
Sigma-Aldrich
Ammonium acetate solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Ammonium acetate, BioUltra, for molecular biology, ≥99.0%
Sigma-Aldrich
Methanol, low water for titration
Sigma-Aldrich
Methanol, NMR reference standard
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
17α-Methyltestosterone, ≥97.0% (HPLC)
Sigma-Aldrich
Isopropyl alcohol, ≥99.7%, FCC, FG
Sigma-Aldrich
Testosterone, purum, ≥99.0% (HPLC)
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Testosterone, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Ammonium acetate, Vetec, reagent grade, 97%