Skip to Content
Merck
  • Evaluation of quadrupole-time-of-flight mass spectrometry in comprehensive two-dimensional gas chromatography.

Evaluation of quadrupole-time-of-flight mass spectrometry in comprehensive two-dimensional gas chromatography.

Journal of chromatography. A (2014-09-03)
Blagoj Mitrevski, Philip J Marriott
ABSTRACT

Quadrupole time-of-flight mass spectrometry (Q-TOFMS) has been evaluated with respect to its applicability in comprehensive two-dimensional gas chromatography (GC×GC). At a maximum acquisition frequency, while approximately 50 full accurate mass spectra on disk were acquired per s (50Hz) in scan mode, the sampling rate in target mode (MS/MS) was strongly dependent on the number of target ions selected. The number of selected precursor ions per time window proportionally decreased the acquisition rate for each ion; one precursor ion ≅31.35Hz; two ions ≅16.68Hz; and for 8 precursor ions, a sampling rate of just 4.18Hz was found. When Q-TOFMS was used in simultaneous mode, where in addition to the acquisition of target ion MS/MS signals, it also collects the full mass spectrum, sampling rates were even lower. It is demonstrated that Q-TOFMS generates sufficient data points over each peak in GC×GC operation in scan mode using TOFMS acquisition only, or is able to collect sufficient data points for relatively wide chromatographic peaks (≥600ms) in the target mode (MS/MS), however only if one or two precursor ions are selected per time window. Mass accuracy was found to perform within specification (<5ppm), even for the fastest acquisition operation (50Hz). Spectral deconvolution is demonstrated to work better in GC×GC than in 1D GC mode. Data visualisation in target GC×GC mode presents difficulties when there are overlapping target windows comprising different numbers of precursor ions.

MATERIALS
Product Number
Brand
Product Description

USP
Acetone, United States Pharmacopeia (USP) Reference Standard
Supelco
Acetone, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetone, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetone, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetone, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Acetone, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetone, puriss., meets analytical specification of Ph. Eur., BP, NF, ≥99% (GC)
Sigma-Aldrich
Acetone, histological grade, ≥99.5%
Sigma-Aldrich
Acetone, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Dicyclohexylamine, 99%
Sigma-Aldrich
Acetone, ≥99%, meets FCC analytical specifications
Sigma-Aldrich
Acetone, natural, ≥97%
Supelco
Acetone, analytical standard
Supelco
Tributyl phosphate, for extraction analysis, ≥99.0% (GC)
Sigma-Aldrich
Tributyl phosphate, 97%
Sigma-Aldrich
Tributyl phosphate, puriss., ≥99.0% (GC)
Sigma-Aldrich
2-Methylheptane, 98%
Sigma-Aldrich
Tributyl phosphate, ≥99%
Tri-n-butyl phosphate, European Pharmacopoeia (EP) Reference Standard
Supelco
Tributyl phosphate, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Triphenyl phosphate, analytical standard
Sigma-Aldrich
Triphenyl phosphate, ≥99%