1.51015
TLC aluminum sheets, silica gel 60 RP-18 F254s MS-grade
pkg of 20 sheets, sheet L × W 5 cm × 7.5 cm, aluminum support
Sign Into View Organizational & Contract Pricing
All Photos(1)
About This Item
Recommended Products
material
aluminum support
silica gel 60 matrix
Quality Level
feature
binder Organic Polymer
fluorescent indicator
packaging
pkg of 20 sheets
technique(s)
TLC-MS: suitable
thin layer chromatography (TLC): suitable
layer thickness
100 μm
sheet L × W
5 cm × 7.5 cm
particle size
10-12 μm
pore size
60 Å medium pore diameter
storage temp.
2-30°C
General description
20 Aluminium sheets 5x7.5
Reference:
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Gertrud Morlock, Wolfgang Schwack
Coupling of planar chromatography to mass spectrometry
TrAC Trends in Analytical Chemistry, Volume 29, Issue 10, 2010, Pages 1157-1171
Analysis Note
Specific surface area(according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Pore volume(N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution):9.7 - 11.7 µm
Layerthickness: 80 - 120 µm
Deviation of layer thickness per plate: ≤ 30 µm
A) Cholesterin test
hRf-values
- cholesterin: 35 - 43
B) Steroid test
- methyltestosterone: 14 - 24
- Reichstein S: 28 - 38- hydrocortisone: 40 - 50
Typical value determined on an activated sheet (120°C, 15 min)
Eluent A) aceton/ water (95/5 v/v)
Eluent B) aceton/ water (60/40 v/v)
C) MS suitability test
- Angiotensin II (signal-to-noiseratio 50ng): ≥ 25
measured with 5000 shots
- Caffeine (signal-to-ratio 5ng): ≥25
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service