Skip to Content
Merck
  • Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-07-27)
Wojciech Ostrowski, Anna Wojakowska, Magdalena Grajzer, Maciej Stobiecki
ABSTRACT

Liquid chromatography coupled to mass spectrometry (MS) with electrospray ionization (ESI) is one of analytical techniques to obtain accurate results of low molecular weight aromatic compounds in biological samples of different origin. The interpretations of mass spectra of these aromatic compounds in the negative spectra registered in the full scan MS mode may be uneasy due to presence of deprotonated molecules [M-H](-) from different co-eluting entities, fragment ions created after the break-up of precursor ions and also ions representing modified molecules clusters. Thus, the first aim of this study was to evaluate general parameters during analysis performed in the full scan MS or MS/MS mode. Secondly, to set general fragmentation rules for aromatic compounds and entities in a complex biological matrix. We established that different groups of low molecular weight phenolic acids form unique adduct ions and additionally registration LC/MS/MS spectra with two different collision energies may allow for differentiating isomeric or isobaric molecules. These findings together with some general fragmentation rules can facilitate identifications of aromatic acids as we outlined in the sample of cold-pressed rose-hip oil and lupine leaves extract.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sinapic acid, ≥98%, powder
Sigma-Aldrich
Homovanillic acid, Fluorimetric reagent
Sigma-Aldrich
Salicylic acid, suitable for plant cell culture
Sigma-Aldrich
Salicylic acid, BioXtra, ≥99.0%
Sigma-Aldrich
p-Coumaric acid, ≥98.0% (HPLC)
Supelco
Methanol, analytical standard
Supelco
Sinapic acid, matrix substance for MALDI-MS, ≥99.0% (T)
Supelco
Mettler-Toledo Calibration substance ME 18555, Benzoic acid, analytical standard, (for the calibration of the melting point system), traceable to primary standards (LGC)
Sigma-Aldrich
Vanillic acid, purum, ≥97.0% (HPLC)
Sigma-Aldrich
Vanillin, tested according to Ph. Eur.
USP
Vanillin Melting Point Standard, United States Pharmacopeia (USP) Reference Standard
Supelco
Melting point standard 182-184°C, analytical standard
Sigma-Aldrich
2-Hydroxy-3-methoxybenzoic acid, 97%
Sigma-Aldrich
3-Hydroxyphenylacetic acid, ≥99%
Sigma-Aldrich
3,5-Dihydroxybenzoic acid, 97%
Sigma-Aldrich
3,4-Dihydroxyphenylacetic acid, 98%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
3-Methoxybenzoic acid, ReagentPlus®, 99%
Sigma-Aldrich
4′-Hydroxy-3′-methoxyacetophenone, 98%
Sigma-Aldrich
3-Hydroxybenzaldehyde, ≥99%
Sigma-Aldrich
Acetovanillone, ≥98%, FG
Sigma-Aldrich
4-Hydroxybenzaldehyde, ≥95.0% (HPLC)
Sigma-Aldrich
4-Hydroxybenzaldehyde, 98%
Sigma-Aldrich
Salicylic acid, puriss. p.a., ≥99.0% (T)
Sigma-Aldrich
Vanillin, ReagentPlus®, 99%
Sigma-Aldrich
Salicylic acid, ReagentPlus®, ≥99%
Sigma-Aldrich
p-Anisic acid, ≥99%, FG
Sigma-Aldrich
Vanillin, natural, ≥97%, FCC, FG
Sigma-Aldrich
Vanillin, ≥97%, FCC, FG
Sigma-Aldrich
Salicylic acid, ACS reagent, ≥99.0%