Skip to Content
Merck
  • Characterization of four popular sweet cherry cultivars grown in Greece by volatile compound and physicochemical data analysis and sensory evaluation.

Characterization of four popular sweet cherry cultivars grown in Greece by volatile compound and physicochemical data analysis and sensory evaluation.

Molecules (Basel, Switzerland) (2015-01-30)
Maria V Vavoura, Anastasia V Badeka, Stavros Kontakos, Michael G Kontominas
ABSTRACT

Volatile compounds, physicochemical and sensory attributes of four sweet cherry cultivars (Canada giant, Ferrovia, Lapins and Skeena) grown in Northern Greece were determined. Eighteen volatile compounds were identified and semi-quantified in cherries using solid phase micro extraction in combination with gas chromatography/mass spectrometry (SPME-GC/MS). Carbonyl compounds were the most abundant in sweet cherry aroma, followed by alcohols, esters and hydrocarbons/terpenes. Cherry cultivars in order of increasing amounts of volatiles were: Lapins < Canada giant < Ferrovia < Skeena. Physicochemical parameters determined included: titratable acidity (TA), pH, total soluble solids (TSS), maturity index (MI) and total phenolic content (TPC). TA ranged between 0.21 and 0.28 g malic acid/100 g fresh weight (FW). The pH ranged between 3.81 and 3.96. TSS ranged between 13.00 and 16.00 °Brix. MI ranged between 51.8 and 75.0. TPC ranged between 95.14 and 170.35 mg gallic acid equivalents (GAE)/100 g FW. Sensory evaluation showed that cherry colour, in order of increasing intensity, was: Canada giant < Ferrovia < Lapins < Skeena. Respective order for cherry firmness was: Canada giant < Lapins ≤ Ferrovia < Skeena and for flavour: Lapins < Canada giant < Skeena ≤ Ferrovia. Correlation of volatiles to physicochemical and sensory attributes showed varying trends.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium chloride, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Sodium chloride, tablet
Sigma-Aldrich
Sodium chloride, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Sodium chloride solution, 5 M
Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium chloride solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Sodium chloride, tested according to Ph. Eur.
Supelco
4-Methyl-2-pentanone, analytical standard
Sigma-Aldrich
Sodium chloride, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
Sodium chloride solution, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
4-Methyl-2-pentanone, ≥99%, FCC
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Sigma-Aldrich
Sodium chloride, random crystals, optical grade, 99.9% trace metals basis
Supelco
SPME fiber assembly polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, metal alloy fiber, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Sigma-Aldrich
Sodium chloride, 99.999% trace metals basis
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME fiber assembly Polydimethylsiloxane (PDMS), df 7 μm(PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga