콘텐츠로 건너뛰기
Merck
  • Pesticide determination in rose petals using dispersive solid-phase extraction followed by gas chromatography-tandem mass spectrometry.

Pesticide determination in rose petals using dispersive solid-phase extraction followed by gas chromatography-tandem mass spectrometry.

Analytical and bioanalytical chemistry (2014-10-27)
Oriane Tascone, Marina Shirshikova, Céline Roy, Uwe J Meierhenrich
초록

Damascena and centifolia roses are cultivated worldwide for their petal extracts that contain key odorant ingredients of perfumes. The analytical identification and quantification of pesticides in rose petals have never been described in the literature. Here, we report on a newly developed method using dispersive solid-phase extraction (d-SPE) cleanup followed by gas chromatography-tandem mass spectrometry for the quantitative determination of multi-residue pesticides in rose petals. Analytes were extracted from the matrix using acetonitrile and a mixture of salts containing magnesium sulfate, sodium citrate, sodium chloride, and sodium sesquihydrate. Samples were cleaned up twice by d-SPE applying primary and secondary amines (PSAs), magnesium sulfate, C18, and graphitized carbon black (GCB). Two fortification levels of 0.05 and 0.5 mg kg(-1) were assessed for method validation purposes. The obtained pesticide recoveries were in the range of 70-120 % with a relative standard deviation (RSD) of less than 20 %. The newly developed method was allowed for the quantification of 57 pesticides residues. It was applied to pesticide residue detection in rose petals from an organic field, without treatment, compared to those from a field with classic phytosanitary treatment using fungicide and/or insecticide. We did not detect pesticide residues in rose petals from the organic field. The classically treated samples of roses contained pesticides such as chlorpyriphos and methidathion which are in accordance with the previous application of these pesticides on the roses. Insecticides were quantified at 0.05 mg kg(-1) rose petal maximum.

MATERIALS
제품 번호
브랜드
제품 설명

Sigma-Aldrich
Citronellyl acetate, ≥95%, FCC, FG
Supelco
Geraniol, analytical standard
Sigma-Aldrich
Eugenol, ≥98%, FCC, FG
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Sigma-Aldrich
Sodium chloride, random crystals, optical grade, 99.9% trace metals basis
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Methane, electronic grade, ≥99.998%
Sigma-Aldrich
Sodium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
Sodium chloride, tested according to Ph. Eur.
Sigma-Aldrich
Sodium chloride solution, BioUltra, for molecular biology, ~5 M in H2O
Supelco
Eugenol, PESTANAL®, analytical standard
Sigma-Aldrich
Acetic acid, for luminescence, BioUltra, ≥99.5% (GC)
Supelco
Sodium chloride, reference material for titrimetry, certified by BAM, >99.5%
Sigma-Aldrich
Eugenol, natural, ≥98%, FG
Supelco
(−)-β-Citronellol, analytical standard
Sigma-Aldrich
Geraniol, 98%
Sigma-Aldrich
Geraniol, natural, ≥97%, FG
Sigma-Aldrich
Sodium chloride, 99.999% trace metals basis
Sigma-Aldrich
Eugenol, ReagentPlus®, 99%
Sigma-Aldrich
Linalool, ≥97%, FCC, FG
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Sodium chloride solution, 0.85%
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Linalool, 97%
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Geraniol, ≥97%, FCC, FG
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Sodium chloride, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium chloride, tablet