콘텐츠로 건너뛰기
Merck
  • Ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry to identify contaminants in water: an insight on environmental forensics.

Ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry to identify contaminants in water: an insight on environmental forensics.

Journal of chromatography. A (2014-05-06)
Ana Masiá, Julian Campo, Cristina Blasco, Yolanda Picó
초록

Ultra-high pressure liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QqTOF-MS) acquiring full scan MS data for quantification, and automatic data dependent information product ion spectra (IDA-MS/MS) without any predefinition of the ions by the user was checked for identifying organic contaminants in water samples. The use of a database with more than 2000 compounds achieved high confidence results for a wide number of contaminants based upon retention time, accurate mass, isotopic pattern and MS/MS library searching. More than 20 contaminants, mostly pharmaceuticals, but also mycotoxins and polyphenols were unambiguously identified. Furthermore, the combination of statistical data analysis using principal component analysis (PCA) followed by empirical formula calculation, on-line database searching and MS/MS fragment ion interpretation achieves not only the successful detection of unknown contaminants but also the selection of those relevant to different types of waters. Unknown compounds, such as C₂₀H₃₄O₃, were identified in waste water showing the prospects of this technique. A group of 42 currently used pesticides were selected as target compounds to evaluate the quantitative possibilities. Mean recoveries and percentage relative standard deviation (RSD) were 48-79% (4-20% RSD). The limit of detections ranged from 0.02 to 2 ng L(-1), with a validated limit of quantification of 2 ng L(-1) for water after solid-phase (SPE) isolation and concentration. The quantitative data obtained using UHPLC-QqTOF-MS were compared with those obtained using conventional LC-MS/MS with a triple quadrupole (QqQ).

MATERIALS
제품 번호
브랜드
제품 설명

Supelco
Simazine solution, 100 μg/mL in methanol, PESTANAL®, analytical standard
Supelco
Omethoate, PESTANAL®, analytical standard
Supelco
Prochloraz, PESTANAL®, analytical standard
Supelco
Hexythiazox, PESTANAL®, analytical standard
Supelco
Imidacloprid, PESTANAL®, analytical standard
Supelco
Dichloromethane, analytical standard
Supelco
Molinate, PESTANAL®, analytical standard
Supelco
Fenthion, PESTANAL®, analytical standard
Supelco
Metolachlor, PESTANAL®, analytical standard
Sigma-Aldrich
Dichloromethane, anhydrous, ≥99.8%, contains 40-150 ppm amylene as stabilizer
Supelco
Methiocarb, PESTANAL®, analytical standard
Supelco
Dichloromethane, Selectophore, ≥99.5%
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Supelco
Simazine, PESTANAL®, analytical standard
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Dichloromethane, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Supelco
Pyriproxyfen, PESTANAL®, analytical standard
Supelco
Dichloromethane solution, contains 10 % (v/v) methanol
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Methylene Chloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Supelco
Prochloraz, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Dichloromethane, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Dichloromethane, puriss. p.a., ACS reagent, reag. ISO, ≥99.9% (GC)
Sigma-Aldrich
Dichloromethane, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Dichloromethane, puriss., meets analytical specification of Ph. Eur., NF, ≥99% (GC)