  • Improving the specificity of nucleic acid detection with endonuclease-actuated degradation.

Improving the specificity of nucleic acid detection with endonuclease-actuated degradation.

Communications biology (2022-04-02)
Roger S Zou, Momcilo Gavrilov, Yang Liu, Dominique Rasoloson, Madison Conte, Justin Hardick, Leo Shen, Siqi Chen, Andrew Pekosz, Geraldine Seydoux, Yukari C Manabe, Taekjip Ha
초록

Nucleic acid detection is essential for numerous biomedical applications, but often requires complex protocols and/or suffers false-positive readouts. Here, we describe SENTINEL, an approach that combines isothermal amplification with a sequence-specific degradation method to detect nucleic acids with high sensitivity and sequence-specificity. Target single-stranded RNA or double-stranded DNA molecules are amplified by loop-mediated isothermal amplification (LAMP) and subsequently degraded by the combined action of lambda exonuclease and a sequence-specific DNA endonuclease (e.g., Cas9). By combining the sensitivity of LAMP with the precision of DNA endonucleases, the protocol achieves attomolar limits of detection while differentiating between sequences that differ by only one or two base pairs. The protocol requires less than an hour to complete using a 65 °C heat block and fluorometer, and detects SARS-CoV-2 virus particles in human saliva and nasopharyngeal swabs with high sensitivity.

MATERIALS
제품 번호
브랜드
제품 설명

Roche