추천 제품
생물학적 소스
rabbit
Quality Level
항체 형태
Ig fraction of antiserum
클론
monoclonal
설명
For In Vitro Diagnostic Use in Select Regions (See Chart)
형태
buffered aqueous solution
기술
immunohistochemistry (formalin-fixed, paraffin-embedded sections): 1:100-1:200
배송 상태
wet ice
저장 온도
2-8°C
시각화
(nuclear,cytoplasm)
일반 설명
P62, also known as Sequestosome-1, is a ubiquitin-binding adapter protein involved in the delivery of ubiquitin-bound protein and organelles to the autophagosome for lysosomal degradation during autophagy. Mutations in p62 have been linked to Paget′s disease and neurodegenerative disorders. P62 is typically degraded during the autophagy process, but can accumulate and/or overexpressed in autophagy-deficient cells. Presence of p62 cytosolic aggregate is used as a marker for autophagy deficiency. Defective autophagy increase oxidative stress and may play a role in tumorigenesis. P62 immunohistochemistry (IHC) diagnostic utility was established for identifying hepatocellular carcinoma (HCC). P62 demonstrates superior sensitivity for HCC compared against glypican-3. Positive p62 staining was found in 100% of HCC but were negative in all non-tumor areas and cirrhotic nodules. Furthermore, a panel consisting of p62, aminoacylase 1, and glypican-3 provides high sensitivity (93.8%) and specificity (95.2%) in the differential diagnosis between well differentiated HCC and high grade dysplastic nodules. P62 expression can also aid in diagnosing drug-induced autophagic vacuolar myopathies. An optimal threshold of at least 11.5% positive fibers provided 100% sensitivity and 100% specificity for autophagic myopathy. While current diagnostic criteria require identification of autophagic vacuoles by electron microscopy, diagnosis with p62 IHC could expedite the process and reduce costliness and large sampling variance associated with electron microscopy.
품질
IVD | IVD | IVD | RUO |
물리적 형태
Solution in Tris Buffer, pH 7.3-7.7, with 1% BSA and <0.1% Sodium Azide
기타 정보
For a copy of the IFU and CofA contact IVDorder@ABCAM.com
For Technical Service please contact: 800-665-7284 or email: service@cellmarque.com
For Technical Service please contact: 800-665-7284 or email: service@cellmarque.com
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.