추천 제품
Grade
HPLC Plus
for residue analysis
vapor density
4.1 (vs air)
vapor pressure
160 mmHg ( 20 °C)
분석
≥99.9%
형태
liquid
포함
amylenes as stabilizer
기술
HPLC: suitable
gas chromatography (GC): suitable
불순물
≤0.02% water
≤0.5 ppb Fluorescence (quinine) at 365 nm
증발 잔류물
≤0.0001%
할로겐화 잔류물
<10 ng/L (as heptachlor epoxide)
refractive index
n20/D 1.445 (lit.)
bp
60.5-61.5 °C (lit.)
mp
−63 °C (lit.)
density
1.48 g/mL at 25 °C
1.492 g/mL at 25 °C (lit.)
λ
H2O reference
UV 흡수
λ: 245 nm Amax: 1.00
λ: 250 nm Amax: 0.30
λ: 275-400 nm Amax: 0.005
응용 분야
food and beverages
SMILES string
ClC(Cl)Cl
InChI
1S/CHCl3/c2-1(3)4/h1H
InChI key
HEDRZPFGACZZDS-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
애플리케이션
- Extraction of active constituents of anti-inflammatory drugs for their analysis by attenuated total reflectance-Fourier transform infrared spectroscopic (ATR-FTIR) methods
- Estimation of ascorbic acid, free phenolic acids, and flavonoids in extracts of chloroform, methanol, water and, acetic acid obtained from two edible leaf samples using reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to photodiode array detector (DAD)
- Preparation of cannabis product extracts for the analysis of delta-9-tetrahydrocannabinol (THC) residues on hands of suspected consumers by ion-mobility spectrometry (IMS)
- Investigation of different solvents to measure their recovery ratios for the extraction of acrylamide and 5-hydroxymethylfurfural (HMF) from seafood samples to develop an HPLC-MS/MS-based method for their quantification
- Extraction of pesticides by direct-immersion single drop micro-extraction (SDME) method from mango samples for their subsequent analysis by GC-MS
- Sample preparation in the profiling of lipids from complex biological samples using off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry
It may be used as:
- Extractant in solvent extraction process.
- A component of the binary mobile phases for liquid chromatography–atmospheric pressure photoionization-mass spectrometry (LC–APPIMS) of triacylglycerol model compounds.
- Solvent for recrystallization.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Oral - STOT SE 3
표적 기관
Central nervous system, Liver,Kidney
Storage Class Code
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK
WGK 3
Flash Point (°F)
does not flash
Flash Point (°C)
does not flash
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.