콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

1.50671

Supelco

ZIC-HILIC (5µm,200Å) 250 x 21.2 mm

stainless steel column, suitable for HPLC, SeQuant®

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115709

material

stainless steel column

Quality Level

Agency

suitable for USP L114

제품 라인

SeQuant®

특징

endcapped: no

제조업체/상표

SeQuant®

파라미터

400 bar pressure
70 °C max. temp.

기술

HPLC: suitable
LC/MS: suitable (Prep LC)
mass spectrometry (MS): suitable (High)

컬럼 길이 × I.D.

25 cm × 21.2 mm

기질

fully porous particle

기질 활성군

ZIC-HILIC bonding phase

입자 크기

5 μm

공극 크기

200 Å pore size

작동 pH

2-7.5

분리 기술

hydrophilic interaction (HILIC)

저장 온도

no temp limit

일반 설명

SeQuant® ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility. The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.The Pore size of 200 Å makes this column perfectly suitable for the separation of larger polar molecules under HILIC conditions.The column dimension of 250 mm length x 21.2 mm ID is the best choice for the semi-preparative separation of polar compounds.Thanks to their favorable retention and robust performance, SeQuant® HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant® ZIC®-HILIC for analysis of melamine and related substances. SeQuant® HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.Learn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection Guide Brochure: A Practical Guide to HPLC - Method Development Guide

분석 메모

Theoretical Plates (N/m) (Cytosine): ≥ 60000
Symmetry (Cytosine): 0.95 - 1.40

법적 정보

SeQuant is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.