Chromolith® CapRod RP-18 endcapped Capillary Columns, L × I.D. 150 mm x 0.05 mm capillary column
material
PEEK column
Quality Level
Agency
suitable for USP L1
제품 라인
Chromolith®
특징
endcapped
포장
1 ea of
라벨링 범위
18% Carbon loading
파라미터
200 bar pressure
기술
HPLC: suitable
LC/MS: suitable (Capillary LC)
mass spectrometry (MS): suitable (High)
컬럼 길이 × I.D.
15 cm × 0.05 mm
기질
monolithic silica
기질 활성군
C18 bonding phase
공극 크기
13 nm mesoporosity
2 μm macroporosity
operating pH range
2-7.5
분리 기술
reversed phase
저장 온도
no temp limit
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
A Chromolith® CapRod capillary column combines the speed of monolithic silica technology with the sensitivity of nano-LC. This enables superior productivity for high throughput, highly sensitive proteomics-LC applications.
Compared to particulate capillary columns, Chromolith® CapRod capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument. Chromolith® CapRod columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).
Why choose Chromolith® CapRod capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces
Chromolith® CapRod RP-18 endcapped can be operated at significantly higher flow rates without loss of performance. The typical flow rate for this 150-0.05 capillary column ranges from 0.2 μL/min to 0.8 μL/min.
Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns
Compared to particulate capillary columns, Chromolith® CapRod capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument. Chromolith® CapRod columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).
Why choose Chromolith® CapRod capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces
Chromolith® CapRod RP-18 endcapped can be operated at significantly higher flow rates without loss of performance. The typical flow rate for this 150-0.05 capillary column ranges from 0.2 μL/min to 0.8 μL/min.
Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns
법적 정보
Chromolith is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
10-13 - German Storage Class 10 to 13