  • Simultaneous extraction and quantification of lamotrigine, phenobarbital, and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high-performance liquid chromatography.

Simultaneous extraction and quantification of lamotrigine, phenobarbital, and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high-performance liquid chromatography.

Journal of separation science (2015-05-09)
Mohammad Asadi, Shayessteh Dadfarnia, Ali Mohammad Haji Shabani, Bijan Abbasi
要旨

A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
リン酸, 85 wt. % in H2O, 99.99% trace metals basis
Sigma-Aldrich
リン酸カリウム 一塩基性, powder, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99.0%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
リン酸, crystalline, ≥99.999% trace metals basis
Sigma-Aldrich
リン酸カリウム 一塩基性, for molecular biology, ≥98.0%
Sigma-Aldrich
リン酸カリウム 一塩基性, ReagentPlus®
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
リン酸, BioUltra, ≥85% (T)
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Sigma-Aldrich
1-デカノール, 98%
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
リン酸カリウム 一塩基性, 99.99% trace metals basis
Sigma-Aldrich
リン酸カリウム 一塩基性, BioUltra, for molecular biology, anhydrous, ≥99.5% (T)
Sigma-Aldrich
リン酸, ≥85 wt. % in H2O, ≥99.999% trace metals basis
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler