コンテンツへスキップ
Merck

GE28-9269-85

HiScreen Butyl-S Fast Flow

Cytiva 28-9269-85

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
13111000
NACRES:
NA.56

ligand

butyl-S

包装

pkg of 1 ea

メーカー/製品名

Cytiva 28-9269-85

パラメーター

1.5 bar (22 psi) (Over the Packed Bed During Operation)
22 psi

ベッドサイズ

7.7 mm × 100 mm

ベッド容積

4.7 mL

カラム内径

7.7 mm

Matrix

6% cross-linked agarose

粒径

45-165 μm

平均直径

90 μm

cleaning

2-14

動作範囲

3-13

適合性

suitable for bioprocess medium

関連するカテゴリー

詳細

HiScreen Butyl S-FF columns are prepacked with Butyl Sepharose 6 Fast Flow hydrophobic interaction chromatography (HIC) resins. The columns are an excellent choice for method optimization and parameter screening.

The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.

If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.

Media prepacked in HiScreen HIC columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

特徴および利点

  • Butyl-S-Sepharose 6 Fast Flow is the least hydrophobic medium in the Sepharose Fast Flow HIC range and particularly useful during the initial stages of a purification process to remove the bulk of impurities.
  • Prepacked, ready-to-use columns for convenient process development optimization.
  • 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
  • Easily connected in series to achieve 2NA cm bed height.
  • Small bed volume gives fast results and minimal sample/buffer consumption.
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.

保管および安定性

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 0.01 M NaOH)
Store at 4 to 30 °C (20% Ethanol)

アナリシスノート

この製品の分析証明書は、www.cytiva.com.

法的情報

HiScreen is a trademark of Cytiva

ピクトグラム

Flame

シグナルワード

Warning

危険有害性情報

保管分類コード

3 - Flammable liquids


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 資料 section.

サポートが必要な場合は、お問い合わせください カスタマーサポート

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)