Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

G005270

GC Analysis of Total Petroleum Hydrocarbons (TPH) on SLB®-5ms (20 m x 0.18 mm I.D., 0.18 μm), Fast GC Analysis

suitable for GC

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

tecniche

gas chromatography (GC): suitable

Parametri analitici

column: SLB-5ms, 20 m x 0.18 mm I.D., 0.18 μm (28564-U)
oven: 70 °C (0.5 min), 20 °C/min to 360 °C (1 min)
inj. temp.: 275 °C
detector: FID, 365 °C
carrier gas: hydrogen, 2.5 mL/min constant
injection: 0.50 μL, 200:1 split
liner: 2 mm I.D. straight
sample: TPH Mix 3, each analyte at 1000 μg/mL in carbon disulfide (861394-U)

applicazioni

environmental

Note legali

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany

Analita

Descrizione

    Hexane
    Heptane
    Octane
    Nonane
    Decane
    Undecane
    Dodecane
    Tetradecane
    Hexadecane
    Octadecane
    Eicosane
    Tetracosane
    Octacosane
    Dotriacontane
    Hexatriacontane
    Tetracontane
    Tetratetracontane
    Vedi tutto (17)

Colonna analitica

N° Catalogo
Descrizione
Determinazione del prezzo

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.