Skip to Content
Merck
  • Biomonitoring method for the determination of polycyclic aromatic hydrocarbons in hair by online in-tube solid-phase microextraction coupled with high performance liquid chromatography and fluorescence detection.

Biomonitoring method for the determination of polycyclic aromatic hydrocarbons in hair by online in-tube solid-phase microextraction coupled with high performance liquid chromatography and fluorescence detection.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-08-08)
Yusuke Yamamoto, Atsushi Ishizaki, Hiroyuki Kataoka
ABSTRACT

Polycyclic aromatic hydrocarbons (PAHs) are formed from the incomplete combustion or pyrolysis of organic matter during industrial processing and various human activities, but human exposure to PAHs has not yet been elucidated in detail. To assess long-term exposure to PAHs, we developed a simple and sensitive method for measuring PAHs in hair by online in-tube solid-phase microextraction using a CP-Sil 19CB capillary column as an extraction device, followed by high-performance liquid chromatography using a Zorbax Eclipse PAH column and fluorescence detection. Seventeen PAHs could be analyzed simultaneously, with good linearity from 20 to 1000pg/mL each as determined using stable isotope-labeled PAH internal standards. The detection limits of PAHs were 0.5-20.4pg/mL. PAHs in human hair samples were extracted by ultrasonication in 50mM NaOH in methanol, and successfully analyzed without any interference peaks, with good recovery rates above 70% in spiked hair samples. Using this method, we evaluated the suitability of using hair PAHs as biomarkers for long-term exposure.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME fiber assortment kit 5, needle size 23 ga, for use with autosampler
Sigma-Aldrich
Benzene, anhydrous, 99.8%
Supelco
SPME fiber assortment kit 4, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assortment kit 4, for use with autosampler, size 24 ga
Supelco
SPME fiber assortment kit 2, for use with manual holder, needle size 24 ga
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
SPME fiber assortment kit 2, for use with autosampler, size 24 ga
Supelco
SPME StableFlex fiber assortment kit, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assortment kit 1, for use with autosampler, needle size 23 ga
Supelco
SPME fiber assortment kit 2, for use with autosampler, needle size 23 ga
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
SPME fiber assortment kit 4, for use with manual holder, size 24 ga
Sigma-Aldrich
Anthracene-d10, 98 atom % D
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
SPME StableFlex fiber assortment kit, needle size 23 ga, for use with autosampler
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, fused silica fiber, for use with manual holder, needle size 23 ga
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME Fiber Assembly Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C