Accéder au contenu
Merck
  • Online capillary solid-phase microextraction coupled liquid chromatography-mass spectrometry for analysis of chiral secondary alcohol products in yeast catalyzed stereoselective reduction cell culture.

Online capillary solid-phase microextraction coupled liquid chromatography-mass spectrometry for analysis of chiral secondary alcohol products in yeast catalyzed stereoselective reduction cell culture.

Journal of chromatography. A (2015-01-08)
Cheanyeh Cheng, Yu-Chuan Nian
RÉSUMÉ

An online solid-phase microextraction coupled liquid chromatography-electrospray ionization-ion trap mass spectrometry was developed for the analysis of trace R- and S-4-phenyl-2-butanol (R- and S-pbol) in salt rich cell culture of Saccharomyces cerevisiae catalyzed stereoselective reduction of 4-pheny-2-butanone (pbone). A Supel-Q PLOT capillary column was used for the extraction and deionized distilled water was used as the extraction mobile phase. The extraction flow rate and extraction time were at 0.1 mL min(-1) and 0.95 min, respectively. The three target analytes, pbone, R-pbol, and S-4-pbol, were desorbed and eluted by the mobile phase of water/methanol/isopropanol (55/25/20, v/v/v) with a flow rate of 0.5 mL min(-1) and analyzed by a chiral column. The mass spectrometric detection of the three target analytes was in positive ion mode with the signal [M+Na](+). The matrix-matched external standard calibration curves with linear concentration range between 0 and 50 μg mL(-1) were used for quantitative analysis. The linear regression correlation coefficients (r(2)) of the standard calibration curves were between 0.9950 and 0.9961. The yeast mediated reduction was performed with a recation culture of yeast incubation culture/glycerol (70/30, v/v) for 4 days. This biotransformation possessed 82.3% yield and 92.9% S-enantomeric excess. The limit of detection (LOD)/limit of quantification (LOQ) for pbone, R-pbol, and S-pbol was 0.02/0.067, 0.01/0.033, and 0.01/0.033 μg mL(-1), respectively. The intra-day and inter-day precisions from repeated measurements were 10.8-21.1% and 11.6-18.7%, respectively. The analysis accuracy from spike recovery was 84-91%.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Glycérol, for molecular biology, ≥99.0%
Sigma-Aldrich
Phosphate de potassium monobasic, ACS reagent, ≥99.0%
Sigma-Aldrich
Glycérol, ACS reagent, ≥99.5%
Sigma-Aldrich
Phosphate de potassium dibasic, ACS reagent, ≥98%
Sigma-Aldrich
Glycérol, ReagentPlus®, ≥99.0% (GC)
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Phosphate de potassium monobasic, powder, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99.0%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Glycérol, ≥99.5%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Divinylbenzene, technical grade, 80%
Sigma-Aldrich
Glycérol, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for electrophoresis, ≥99% (GC)
Sigma-Aldrich
Glycérol solution, 83.5-89.5% (T)
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, Absolute - Acetone free