Recommended Products
material
303 stainless steel nut (locking nut and tool)
polysulfone ring(s) (safety ring )
Quality Level
product line
NovaSeptum® GO
feature
autoclavable
parameter
-80-150 °C temp. range (-112-302 °F)
6 bar max. pressure (87 psi) at ±25 °C
application(s)
cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pathogen testing
pharma/biopharma processes
pyrogen testing
sterile sampling
sterility testing
viral therapy
storage temp.
room temp
General description
Specificity
Application
Components
- Magazine: Glass fiber reinforced Polysulfone (PSU)
- Safety ring: PSU
- Locking nut and tool: Stainless steel in compliance with SS2346, ASTM® 303
- Locking tag: Polyamid/stainless steel
- Wetted materials: Stainless steel in compliance with 316L EN 1.4435, ASME SA 479/ASTM® A 479, EN 10 272
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
NovaSeptum® GO sterile sampling unit with 15 mL single-use conical tube for small volume and endotoxin sampling. Closed design for aseptic process. Reduce product loss and risks of contamination. Available in single and manifold sampling format. Easily integrated into stainless-steel system via multi-use connection types (TC, in-line, ingold®).
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service