Skip to Content
Merck
  • Sensitivity enhancement in direct coupling of supported liquid membrane extractions to capillary electrophoresis by means of transient isotachophoresis and large electrokinetic injections.

Sensitivity enhancement in direct coupling of supported liquid membrane extractions to capillary electrophoresis by means of transient isotachophoresis and large electrokinetic injections.

Journal of chromatography. A (2015-03-10)
Pavla Pantůčková, Pavel Kubáň, Petr Boček
ABSTRACT

Enhanced sensitivity for determination of basic drugs in body fluids was achieved by in-line coupling of extraction across supported liquid membrane (SLM) to large electrokinetic injection and transient isotachophoresis-capillary zone electrophoresis (tITP-CZE) in commercial CZE instrument. Twelve cm long tITP plug of 300mM ammonium acetate was formed in the separation capillary just before the electrokinetic injection of acceptor solution containing nortriptyline, haloperidol and loperamide extracted across the SLM. The tITP plug ensured efficient stacking and preconcentration of the injected basic drugs due to the tITP action of ammonium and the drugs were then separated by CZE using 5.2M acetic acid as background electrolyte. No interferences were observed from highly-abundant body fluid species (NaCl and human serum albumin) due to the excellent clean-up properties of SLMs and analytical sensitivity increased up to 340 times compared to SLM extractions coupled in-line to CZE with standard hydrodynamic injections. The SLM-tITP-CZE method was characterized by good repeatability (RSDs of peak areas below 7.8%), linearity over two orders of magnitude (r(2) better than 0.994) and limits of detection (defined as 3×S/N) between 3 and 45μg/L. Interfacing of SLM extractions to CZE instrumentation was achieved by low-cost, disposable micro-extraction devices, which can be routinely prepared in every analytical laboratory. These devices eliminated sample carry-over, minimized the need for manual sample handling and ensured fully automated determination (including extraction, injection, preconcentration and separation) of the three basic drugs in 20μL of untreated body fluids.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Millipore
Bifido Selective Supplement B, suitable for microbiology
Sigma-Aldrich
Pyrvinium pamoate salt hydrate, ≥98% (HPLC)
Sigma-Aldrich
Ethanol, purum, fine spirit, denaturated with 2% 2-butanone, F25 MEK1, ~96% (based on denaturant-free substance)
Sigma-Aldrich
Ethanol, purum, fine spirit, denaturated with 4.8% methanol, F25 METHYL1, ~96% (based on denaturant-free substance)
Sigma-Aldrich
Ethyl alcohol, Pure 200 proof, for molecular biology
Sigma-Aldrich
Ethanol, purum, absolute ethanol, denaturated with 4.8% isopropanol, A15 IPA1, ≥99.8% (based on denaturant-free substance)
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
Ethanol, purum, absolute ethanol, denaturated with 2% 2-butanone, A15 MEK1, ≥99.8% (based on denaturant-free substance)
Supelco
Ethanol, standard for GC
Sigma-Aldrich
Ethanol, purum, secunda spirit, denaturated with 2% 2-butanone, S15, ~96% (based on denaturant-free substance)
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, purum, ≥99.0% (TLC)
Sigma-Aldrich
Ethanol, for residue analysis
Sigma-Aldrich
Ethanol, tested according to Ph. Eur.
Sigma-Aldrich
Ethanol, BioUltra, for molecular biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Acetic acid, glacial, ≥99.99% trace metals basis
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Ammonium acetate solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Ammonium acetate, BioUltra, for molecular biology, ≥99.0%
Sigma-Aldrich
Sodium chloride, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Sodium chloride, tablet
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%