Saltar al contenido
Merck
  • Method optimization by solid-phase microextraction in combination with gas chromatography with mass spectrometry for analysis of beer volatile fraction.

Method optimization by solid-phase microextraction in combination with gas chromatography with mass spectrometry for analysis of beer volatile fraction.

Journal of chromatography. A (2006-05-12)
Olivia Pinho, Isabel M P L V O Ferreira, Lúcia H M L M Santos
RESUMEN

A simple and sensitive method for the analysis of beer volatile compounds was optimised using headspace solid-phase microextraction (SPME) and gas chromatography with mass detection. Headspace SPME using a 75 microm Carboxen-polydimethylsiloxane (CAR-PDMS) fiber provided effective sample enrichment and enabled extraction of a wide variety of compounds. The reproducibility depended on the compounds, with a mean value of 1.4% for alcohols, 3.3% for ethers, 6.7% for aldehydes, 3.4% for acids, 1.7% for aromatic compounds, 2.4% for esters, 7.4% for hydrocarbons, 1.8% for alicyclic compounds, and 3.4% for heterocyclic compounds. The optimised methodology can be used to compare volatile profile from different types of beers and eventually to study the evolution of a particular beer during aging.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, StableFlex
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, for use with manual holder
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
ORBO 90 Carboxen® 564 (20/45) 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, needle size 24 ga, StableFlex, for use with autosampler
Supelco
ORBO-78 400/200 MG PK/25, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Columna capilar para GC Carboxen®-1010 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Columna capilar para GC Carboxen®-1006 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Columna capilar para GC Carboxen®-1010 PLOT, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Fibra de carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Columna capilar para GC Carboxen®-1006 PLOT, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm
Supelco
Carboxen® 1000 Reversible SPE Tube, 200 mg/mL, pk 30
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Carboxen® Adsorbent, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
Tubo absorbente ORBO-93, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
Fibra de divinilbenceno/carboxeno/polidimetilsiloxano (DVB/CAR/PDMS) de SPME, for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 1 cm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 569, 20-45 mesh, bottle of 500 g