Skip to Content
Merck
  • Discovery of syn-/anti-cocaine-N-oxide diastereomers in unwashed postmortem hair via LC-MS-MS.

Discovery of syn-/anti-cocaine-N-oxide diastereomers in unwashed postmortem hair via LC-MS-MS.

Journal of analytical toxicology (2014-05-02)
Christine M Marsh, Lindsey R Crawley, Sarah K Himes, Roman Aranda, Mark L Miller
ABSTRACT

The discovery of two cocaine-N-oxide (CNO) diastereomers, syn- and anti-CNO, is reported for the first time. Prior to this study, only one structural form of CNO was known to exist and has not been analyzed in hair before. CNO is a metabolite of cocaine (COC) and may be considered as an additional biomarker of COC use, along with other known COC metabolites. The analysis of COC in hair for forensic applications is under scrutiny due to the possibility of external contamination. A qualitative liquid chromatography-tandem mass spectrometry method was developed, validated and applied to unwashed postmortem hair samples from drug users. The limit of detection in hair was 8 pg/mg (using 10 mg of unwashed hair) for each CNO diastereomer. The presence of both syn- and anti-forms of CNO was verified in vivo using hair samples collected from known COC-using individuals. Due to the low levels of CNO, it will not always be detectable in COC user hair. In the hair samples analyzed, syn-CNO was detected in more samples than anti-CNO. The stereoselective N-oxidation of COC which favors syn-CNO could have a diagnostic value for COC ingestion determination in hair analysis.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Hydrogen peroxide solution, tested according to Ph. Eur.
Millipore
Hydrogen peroxide solution, 3%, suitable for microbiology
Sigma-Aldrich
Hydrogen peroxide solution, 30 % (w/w) in H2O, contains stabilizer
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Hydrogen peroxide solution, 34.5-36.5%
Supelco
Hydrogen peroxide solution, ≥30%, for trace analysis
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, NMR reference standard
Codeine, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Hydrogen peroxide solution, 50 wt. % in H2O, stabilized
Sigma-Aldrich
Hydrogen peroxide solution, contains inhibitor, 30 wt. % in H2O, ACS reagent
Sigma-Aldrich
Hydrogen peroxide solution, contains inhibitor, 30 wt. % in H2O, meets USP testing specifications
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Hydrogen peroxide solution, contains inhibitor, 35 wt. % in H2O
Supelco
Hydrogen peroxide solution, 30 % (w/w), for ultratrace analysis
Supelco
Codeine solution, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Codeine solution, 1 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
(±)-Brompheniramine maleate salt, European Pharmacopoeia (EP) Reference Standard
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material