Skip to Content
Merck
  • Determination of ochratoxins in nuts and grain samples by in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.

Determination of ochratoxins in nuts and grain samples by in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.

Journal of chromatography. A (2011-12-20)
Keita Saito, Risa Ikeuchi, Hiroyuki Kataoka
ABSTRACT

A simple and sensitive method for the determination of ochratoxins A and B in nuts and grain samples was developed using an automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). Ochratoxins were separated within 5 min by high-performance liquid chromatography using an Inertsil ODS-3 column with 5mM anmonium acetate/acetonitrile (65/35, v/v) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for mass spectrometric detection of ochratoxins. The pseudo molecular ion [M+H](+) was used to detect ochratoxins with selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample using a Carboxen-1006 PLOT capillary column as an extraction device. The extracted ochratoxins were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME/LC-MS with SIM method, good linearities of the calibration curves (r=0.9993 for ochratoxin A and r=0.9989 for ochratoxin B) were obtained in the concentration range from 0.5 to 20 ng/mL. The detection limits (S/N=3) for ochratoxins A and B were 92 and 89 pg/mL, respectively. The in-tube SPME method showed above 15-19-fold greater sensitivity than the direct injection method (10 μL injection). The within-day and between-day precisions (relative standard deviations) were below 5.1% and 7.7% (n=6), respectively. This method was applied successfully to analysis of nuts and grain samples without interference peaks. The recoveries of ochratoxins spiked into extraction solution from nut samples were above 88%. Ochratoxins were detected at 0.7-8.8 ng/g levels in various nuts and grain samples.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, for use with autosampler, needle size 23 ga, metal alloy fiber
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
Carboxen® Adsorbent, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
Carboxen® Adsorbent, matrix Carboxen® 569, 20-45 mesh, bottle of 500 g
Supelco
Carboxen® 1000 Reversible SPE Tube, 200 mg/mL, pk 30
Supelco
ORBO-93 Sorbent Tube, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPME fiber assembly Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Carboxen® Adsorbent, matrix Carboxen® 564, 20-45 mesh, pack of 144 × 290 mg
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME fiber assembly Carboxen/Polydimethylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga